HomeMy WebLinkAbout2501 OrdinanceORDINANCE NO. 2501 AN ORDINANCE of the City of Pasco adopting the 1982 Edition of the Uniform Building Code; adopting the 1983 Supplement to the Uniform Building Code; adopting the Uniform Building Standards; adopting regulations for Barrier Free Facilities; and adopting the Uniform Building Code Appendix Chapters 1, 7, 11, 32, 49, and 70; all together with appropriate amendments and substitions thereto THE CITY COUNCIL OF THE CITY OF PASCO DOES ORDAIN AS FOLLOWS: Section 1. Section 16.04.010 of the Pasco Municipal Code be and the same is hereby amended to read as follows. 16.04.010 ADOPTION OF UNIFORM BUILDING CODE AND SUPPLEMENT. The Uniform Building Code with Appendix Chapters 1, 7, 11, 32, 49, and 70, 1982 Edition, and the 1983 supplement, both prepared by the International Conference of Building Officials, and as herein amended or revised, is adopted by the city, and all buildings herein- after erected or constructed, enlarged, repaired, removed, demolished, or converted shall be done in conformity with the provisions of said codes, except as expressly provided herein. Three (3) copies of said codes have heretofore been filed and are now on file in the office of the city clerk for use and examination by the public as required by law prior to adoption of the ordinance codified in this chapter. Section 2. Section 16.04.110 of the Pasco Municipal Code be and the same is hereby amended to read as follows: 16.04.110 AMENDMENT OF UBC SECTION 1204. Section 1204 of the Uniform Building Code shall be amended to read as follows: Section 1204 Exit Facilities. Stairs, exits and smokeproof enclosures shall be as specified in Chapter 33. All stairs and exits in Group R, Division 1 Occupancies shall open directly upon a street or alley or upon a yard or court not less than four feet in width directly connected to a street or alley by means of a passageway not less in width than the stairway opening into such passageway and not less than seven feet in height. Buildings more than one story in height shall have no transoms or ventilating openings from guest rooms to public corridors. Door openings from guest rooms to public corridors shall be protected as specified in Section 3305(h). Every sleeping room below the fourth story shall have at least one operable window or exterior door approved for emergency escape or rescue. The units shall be operable from the inside to provide a full clear opening without the use of separate tools. -2- All escape or rescue windows from sleeping rooms shall have a minimum clear opening of 5.7 square feet. The minimum net clear opening height dimension shall be 24 inches. The minimum net clear opening width dimension shall be 20 inches. Where windows are provided as a means of escape or rescue, they shall have a finished sill height not more than 44 inches above the floor. Bars, grilles, grates or similar devices may be installed on emergency escape or rescue windows or doors, provided: 1) Such devices are equipped with approved release mechanisms which are openable from the inside without use of a key or special knowledge or effort; and 2) The building is equipped with smoke detectors installed in accordance with Section 1210. Section 3. Section 16.04.160 of the Pasco Municipal Code be and the same is hereby amended to read as follows: 16.04.150 AMENDMENT OF UBC SECTION 2305(d). Section 2305 (d) of the Uniform Building Code shall be amended to read as follows: Section 2305(d). Snow Loads. Snow loads full or unbalanced shall be considered in place of loads set forth in Table No. 23-C, where such loading will result in larger members or connections. Potential accumulation of snow at valleys, parapets, roof structures, and offsets in roofs of uneven configuration shall be considered. Snow loads shall be twenty-five pounds per square foot. Section 4. Section 16.04.170 of the Pasco Municipal Code be and the same is hereby repealed. Section 5. Section 16.04.180 of the Pasco Municipal Code be and the same is hereby amended to read as follows: 16.04.180 AMENDMENT OF UBC SECTION 2516(c)2. Section 2516(c)2 of the Uniform Building Code shall be amended to read as follows: Section 2516(c)2. Underfloor Clearance. Wood joists or bottom of wood floors closer than eighteen inches, or wood girders closer than twelve inches to the ground underfloor areas and their supports, shall be of treated wood or all heartwood of approved naturally durable species as listed in Section 2517(c)3. Accessible underfloor areas shall be provided with an exterior twenty-four inch by twenty-four inch access crawl hole. The well for the access hole must have a minimum horizontal distance of twenty- four inches and, if there is mechanical equipment under the house, the opening must be capable of removing the largest piece of equipment. -3- Section 6. Section 16.04.190 of the Pasco Municipal Code be and the same is hereby repealed. Section 7. Section 16.04.200 of the Pasco Municipal Code be and the same is hereby amended to read as follows: 16.04.200 AMENDMENT OF UBC SECTION 2517(g)2. Section 2517 (g)2 of the Uniform Building Code shall be amended to read as follows: Section 2517(g)2. Framing Details. Studs shall be placed with their wide dimension perpendicular to the wall. Not less than three studs shall be installed at each corner of an exterior wall. Bearing and exterior wall studs shall be capped with double top plates installed to provide overlapping at corners and at inter- sections with other partitions. End joints in double top plates shall be offset at least 48 inches. When bearing studs are spaced at 24-inch intervals and top plates are less than two 2 by 6 by 4 menbers and when the floor joists, floor trusses or roof trusses which they support are spaced at more than 16-inch intervals, such joists or trusses shall bear within 5 inches of the studs beneath or a third plate shall be installed. Interior nonbearing partitions may be capped with a single top plate installed to provide overlapping at corners and at inter- sections with other walls and partitions. The plate shall be continuously tied at joints by solid blocking at least 16 inches in length and equal in size to the plate or by 1/8-inch by 11/2-inch metal ties with spliced sections fastened with two 16d nails on each side of the point. Studs shall have full bearing on a plate or sill not less than 2 inches in thickness having a width not less than that of the wall studs. Section 8. Section 16.04.210 of the Pasco Municipal Code be and the same is hereby amended to read as follows: 16.04.210 AMENDMENT OF UBC SECTION 2907(a). Section 2907(a) of the Uniform Building Code shall be amended to read as follows: Section 2907(a). Footings: General. Footings and foundations, unless otherwise specifically provided, shall be constructed of masonry, concrete, or treated wood in conformance with UBC Standard No. 29-3. In all cases, footings and foundations shall extend below the frost line; the minimum frost line depth shall be twenty-four inches. Footings of concrete and masonry shall be of solid material; any hollow core masonry unit foundation that exceeds twenty-four inches vertical height shall have all cores filled to a minimum of six (6) inches above finish grade with mortar or other material acceptable to the administrative authority. Foundations supporting wood shall extend at least 6 inches above the adjacent finish grade. -4- Section 9. Section 16.04.220 of the Pasco Municipal Code be and the same is hereby repealed. Section 10. Section 16.04.230 of the Pasco Municipal Code be and the same is hereby repealed. Section 11. Section 16.04.240 of the Pasco Municipal Code be and the same is hereby amended to read as follows: Section 16.04.240 AMENDMENT OF UBC SECTION 3205(a). Section 3204(a) of the Uniform Building Code shall be amended to read as follows: Section 3205(a) Attics: Access. An attic access opening shall be provided in the ceiling of the top floor of ,buildings with combustible ceiling or roof construction. The opening shall be located in a corridor, hallway, or garage of an R-3 occupancy and in the corridor or hallway of any other occupancy. The opening shall be not less than 22 inches by 30 inches. Thirty (30) inch minimum clear head room shall be provided above the access opening. Attics with a maximum vertical clear height of less than 30 inches need not be provided with access openings. Section 12. Section 16.04.245 of the Pasco Municipal Code be and the same is hereby amended to read as follows: Section 16.04.245 ADDITION TO UBC SECTION 3304(k). Section 3304(k) shall be added to the Uniform Building Code to read as follows: Section 3304(k) Door Construction All exterior doors installed for use in habitable portions of Group R occupancies, if of wood construction, shall be of solid core design; if of metal construction, shall be fully insulated Section 13. Section 16.04.270 of the Pasco Municipal Code be and the same hereby is enacted to read as follows: 16.04.270 AMENDMENT OF UBC APPENDIX SECTION 108(b). . Section 108(b) of the Uniform Building Code Appendix shall be amended to read as follows: Section 108(b) Compliance Period. The building inspector shall provide a minimum of thirty (30) days but not more than twelve (12) months for compliance with the requirements of this chapter; the time periods prescribed herein and/or by the building inspector shall commence on the date of receipt, by the owner of the building, of written notice of necessary corrections and the compliance period prescribed by the building inspector. ED by th City Council of the City of Pasco this r 7 , 1984. stello, City Attorney Wells, City Clerk AP FORM• -5- Section 14. Section 16.04.280 of the Pasco Municipal Code be and the same hereby is enacted to read as follows: 16.04.280 DELETION OF UBC APPENDIX SECTION 111. Section 111 of the Uniform Building Code Appendix shall be deleted. Section 15. Section 16.04.300 of the Pasco Municipal Code be and teh same hereby is enacted to read as follows: 16.04.300 RESOLUTION OF CODE CONFLICTS. In case of conflict among the following construction codes, the code first named below shall govern over those following: (1) Uniform Building Code; (2) Uniform Mechanical Code; (3) Uniform Fire Code, (4) Uniform Plumbing Code. Section 16. This ordinance shall be in full force and effect after its passage and publication as required by law. day o ATTEST. AFFIDAVIT OF PUBLICATION COUNTY OF Franklin )ss STATE OF WASHINGTON Eileen Scott , being first duly sworn on oath deposes and says she theprincipal clerk of the Tri-City Herald, a daily newspaper That said newspaper is a legal newspaper and has been approved as a legal newspaper by order of the superior court in the county in which it is published and it is now and has been for more than six months prior to the date of the publication here- inafter referred to, published in the English language continually as a daily newspaper in Franklin County, Washington, and is now and during all of said time was printed in an office maintained at the aforesaid place of publication of said newspaper That the annexed is a true copy of a legal ad "Ordianee NO. 250/...n as it was printed in the regular and enye issue of the Tri City Herald itself and not in a supplement thereof, for a period of consecutive weeks, commencing on the 8th day of June ,184 , and ending on the 8th day of June , 1984, and that said newspaper was regularly cittributed to its subscribers during all of this period 009 00 That the full amount of $ 0 has been paid in full, also at the rate of 40 inches @ $6.90 . *276.00 9 Subscribed and sworn to before me this 18th d ay o f June ,1984 Notary Public in and for the State of Washington, residing at Pasco ORDINANCE NO 2501 AN ORDINANCE of the City I of Pasco adopting the 1982 'Edition of the Uniform I Building Code adopting the 1983 Supplement to the 'Uniform Building Code adopting the Uniform Build ing Standards adopting regulations for Barrier Free , Facilities and adopting the Uniform Building Code Ap- ' pendix Chapters 1 7 11 j32 49 and 70 all together with appropriate amend ments and substitions I thereto THE CITY COUNCIL OF THE CITY OF PASCO DOES ORDAIN AS FOL- LOWS Section 1 Section / 16 04 U10 of the Pasco Mu nicipal Code be and the I same hereby amended to read as follows 16 04 010 ADOPTION OF UNIFORM BUILDING CODE AND SUPPLE ' MENT The Uniform Build mg Code with Appendix 1 Chapters 1 7 11 32 49 and 70 1982 Edition and the 1983 supplement both prepared by the Interns tionaf Conference of Build mg Officials and as herein amended or revised 'is adopted by the city and all buildings hereinafter erected or constructed en- larged repaired removed demolished or converted shall be done in conformity with the provisions of said codes except as expressly provided herein , Three (3) copies of said 11 codes have heretofore n ' been filed and are now on file in the office of the City Clerk for use and examine lion by the public as re I quired by law prior to adoption of the ordinance codified in this chapter Section 2 Section 16 04 110 to the Pasco Mu I nicipal Code be and the same is hereby amended to I read as follows 16 04 110 AMENDMENT I OF UBC SECTION 1204 Section 1204 of the Um form Building Code shall be I amended to read as, fol I lows I Section 1204 Exit Facili- ties Stairs exits and smo 1 keproof enclosures shall be as specified in Chapter 33 All stairs and exits in Group ' R Division 1 Occupancies shall open directly upon a 1 street or alley or upon a yard or court not less than L four feet in width directly T connected to a street or alley by means of a passe , geway not less than seven feet in height Buildings more than one story in height shall have no transoms or ventilating openings from guest rooms to public corridors Door openings from guest rooms to public corridors shall be protected as specified in ? Section 3305(h) Every sleeping room below the fourth story shall have at least one operable window or exterior door ap proved for emergency es cape or rescue The units shall be operable from the inside to provide a full clear opening without the use of separate tools All escape or rescue win dows from sleeping rooms shall have a minimum clear opening of 5 7 square feet The minimum net clear opening height dimension shall be 24 inches The minimum net clear opening width dimension shall be 20 inches Where windows are provided as a means of es cape or rescue they shall -- - have a finished sill height not more than 44 inches above the floor Bars grills grates or similar devices may be in- stalled on emergency es cape or rescue windows or doors provided 1) Such devices are equipped with approved re lease mechanisms which are openable from the in side without use of a key or special knowledge or effort and 2) The building is equipped with smoke de tectors installed in accord ance with Section 1210 Section 3 Section 16 04 160 of the Pasco Mu nicipal Code be and the same is hereby amended to read as follows 16 04 150 AMENDMENT OF UBC SECTION 2305(d) Section 2305 (d) of the Uni- form Building Code shall be amended to read as fol lows Section 2305(d) Snow Loads Snow loads full or unbalanced shall be con sidered in place of loads set forth in Table No 23-C where such loading will re suit in larger members or connections Potential accumulation of snow at valleys par apets roof structures and offsets in roofs of uneven configuration shall be con- sidered Snow loads shall be twenty five pounds per square foot Section 4 Section 16 04 170 of the Pasco Mu recipe! Code be and the same hereby repealed Section 5 Section 16 04 180 of the Pasco Mu nictpal Code be and the same is hereby amended to read as follows 16 04 180 AMENDMENT OF UBC SECTION 2516(c)2 Section 2516(c)2 of the Uniform Building Code shall be amended to read as follows Section 2516(c)2 Un- derfloor Clearance Wood joists or bottom of wood floors closer than eighteen inches or wood girders closer than twelve inches to the ground underfloor areas and their supports, shall be of treated wood or all heartwood of approved naturally durable species as listed in Section 2517(c)3 Accessible underfloor areas shall be provided with an exterior twenty four inch by twenty four inch ac cess crawl hole The well for the access hole must have a minimum horizontal distance of twenty four inches and if there is me chanical equipment under the house the opening must be capable of remov log the largos piece of equipment Section 6 Section 16 04 190 of the Pasco Mu recipal Code be and the same Is hereby repealed Section 7 Section 16 04 200 of the Pasco Mu- nicipal Code be and the same is hereby amended to read as follows 16 04 200 AMENDMENT OF UBC SECTION 2517(9)2 Section 2511(g)2 of the Uniform Building Code shall be amended to read as follows Section 2517(g)2 Fram- ing Details Studs shall be placed with their wide di mension perpendicular to the wall Not less than three studs shall be installed at each corner of an exterior wall Bearing and exterior wall studs shall be capped with double top plates installed to provide overlapping at corners and at intersec- tions with other partitions End joints in double top plates shall be offset at east 48 inches When bearing studs are spaced at 24-inch intervals and top plates are less than two 2 by 6 by 4 members and when the floor joists floor trusses or roof trusses which they support are spaced at more than 16 inch intervals such joists or trusses shall bear within 5 inches of the studs beneath or a third plate shall be in- stalled Interior nonbearing pare bons may be capped with a single top plate installed to provide overlapping at cor- ners and at intersections with other walls and pare bons The plate shall be continuously tied at joints by solid blocking at least 16 inches in length and equal in size to the plate or by 1/8 inch by 11/2 inch metal ties with spliced sections fas tened with two 16d nails on each side of the point Studs shall have full bearing on a plate or sill not less than 2 inches in thick ness having a width not less than that of the wall studs Section 8 Section 16 04 210 of the Pasco Mu moped Code be and the same is hereby amended to read as follows 16 04 210 AMENDMENT OF UBC SECTION 2907(a) Section 2907(a) of the Uni- form Building Code shall be amended to read as fol lows Section 2907(a) Foot- ings General Footings and foundations unless otherwise specifically pro- vided shall be constructed of masonry concrete or treated wood in confor mance with UBC Standard No 29 3 In all cases foot- ings and foundations shall extend below the frost line the minimum frost line depth shall be twenty-four inches Footings of con- crete and masonry shall be of solid materials any hol low core masonry unit foun- dation that exceeds twenty- four inches vertical height shall have all cores filled to a minimum of six (6) inches above finish grade with mortar or other material ac- ceptable to the administra- tive authority Foundations supporting wood shall ex- tend at least 6 inches above the adjacent finish grade Section 9 Section 16 04 220 of the Pasco Mu nicipal Code be and the same is hereby repealed Section 10 Section 16 04 230 of the Pasco Mu nicipal Code be and the same is hereby repealed Section 11 Section 16 04 240 of the Pasco Mu nictpal Code be and the same is hereby amended to read as follows Section 16 04 240 AMENDMENT OF UBC SECTION 3205(a) Section 3204(a) of the Uniform Building Code shall be amended to read as fol lows Section 3205(a) Attics Access An attic access opening shall be provided in the ceiling of the top floor of buildings with combust' ble ceiling or roof construc- tion The opening shall be located in a corridor hall way or garage of an Fl 3 occupancy and in the corn dor or hallway of any other occupancy The opening shall be not less than 22 Tnches by 30 inches Thirty (30) inch min imum clear head room shall be provided above the ac cess opening Attics with a maximum vertical clear height of less than 30 inches need not be pro vided with access open ings Section 12 Section 16 04 245 of the Pasco Mu- nicipal Code be and the same is hereby amended to read as follows Section 16 04 245 ADDI- TION TO UBC SECTION 3304(k) Section 3304(k) shall be added to the Uni form Building Code to read as follows Section 3304(k) Door Construction All exterior doors installed for use in habitable portions of Group R occupancies if of wood construction shall be of solid core design if of metal construction shall be fully insulated Section 13 Section 16 04 270 of the Pasco Mu rucipal Code be and the same is hereby is enacted to read as follows 16 04 270 AMENDMENT OF UBC APPENDIX SEC- TION 108(b) Section 108(b) of the Uniform Build- ing Code Appendix shall be amended to read as fol lows Section 108(b) Compli- ance Period The building inspector shall provide a minimum of thirty (30) days but not more than twelve (12) months for compliance with the requirements of this chapter the time pen ods prescribed herein and/or by the building in spector shall commence on the date of receipt by the owner of the building of written notice of necessary corretions and the comp!' ance period prescribed by the building inspector Section 14 Section 16 04 280 of the Pasco Mu nicipal Code be and the same hereby is enacted to read as follows 16 04 280 DELETION OF UBC APPENDIX SEC TION 111 Section 111 of the Uniform Building Code Appendix shall be deleted Section 15 Section 16 04 300 of the Pasco Mu nocipal Code be and the same hereby is enacted to read as follows 16 04 300 RESOLUTION OF CODE CONFLICTS In case of conflict among the following construction codes the code first named below shall govern over those following (1) Uniform Building- Code (2) Uniform Mechanical Code (3) Uniform Fire Code (4) Uniform Plumbing Code Section 16 This ordi nance shall be in full force and effect after its passage and publication as required, by law PASSED by the City! Council of the City of Pasco this 4 day of June 1984 s-Joe %N Jackson Mayor ATTEST $ Evelyn Wells City Clerk APPROVED AS TO FORM s Greg Rubstello City Attorney Legal No 16956. June 8, 1984 , 198 4 _ ,Zee,----,----) ) 81h day of June AFFIDAVIT OF PUBLICATION COUNTY OF PrP 1110 1 /1 ) )ss STATE OF WASHINGTON ) Eileen Scntt being first duly sworn on oath deposes and says she is thePrQ1Pai clerk of the Tn City Herald, 3.1-1 a daily newspaper That said newspaper is a legal newspaper and has been approved as a legal newspaper by order of the superior court in the county in which it is published and it is now and has been for more than six months prior to the date of the publication here inafter referred to, published in the English language continually as a daily newspaper in Franlain , County, Washington, and is now and during all of said time was printed in an office maintained at the aforesaid place of publication of said newspaper That the annexed is a true copy of a legal ad "Ordiance NO. 2501..." as it was printed in the regular and entie issue of the Tn City Herald itself and not in a supplement thereof, for a period of consecutive weeks, commencing on the etb day of June ,i434 , and ending on the 8th day of Jung, , 1984, and that said newspaper was regularly distributed to its subscribers during all of this period That the full amount of $ 276,00 has been paid in full, also at the rate of 40 inch e$ @ $6,90 . $276.00. . Subscribed and sworn to before me this L , Notary Public in and for the State of Washington, residing at Pasco FINANCE DEPARTMENT 1S09) 545-1401 Sean 726 3 WI ew Wells ity Clerk P 0 BOX 293 412 WEST CLARK PASCO, WASHINGTON 99301 June 4, 1984 In City Herald P 0 Box 2608 Pasco, Washington 99302 Gentlemen Please publish Ordinance Nos. 2501, 2502 and 2503 on the following date June 8, 1984 Please send two (2) Affidavits of Publication for each. Sincer ly yours,