Loading...
HomeMy WebLinkAboutBilfinger Water Technologies Butterfield WTP Intake Screens C7-WT-2R-14-06STATE OF WASHINGTON CONTRACT BUTTERFIELD WTP -INTAKE SCREENS Project No. CP7-WT-2R-14-06 ss COUNTY OF FRANKLIN ) int J� i This agreement and contract made and entered into in duplicate this A4 day of QGtabor,2014 by and between the City of Pasco a municipal corporation, hereinafter called the City and BILFINGER WATER TECHNOLOGIES. INC. hereinafter called the Contractor. WITNESSETH: WHEREAS, the City has caused to be prepared certain plans and specifications for improvements in and for the City of Pasco and the Contractor did on the 15th day of September, 2014 submit to the City of Pasco, Washington, a Proposal to furnish all equipment, labor, materials and appurtenances, and agreed to accept for and in full consideration of the sums fully stated and set forth in said Proposal as full compensation for the completed work, with said compensation due and payable 30 days from the date of delivery of said equipment to the City. At the request of the City and per the revisions to the plans and specifications resubmitted to the Contractor, a revised Proposal was submitted to the City on the 29th day of October, 2014 and hereby replaces the previous proposal. WHEREAS, the said specifications and Proposal fully and accurately described the terms and conditions upon which the Contractor proposes to furnish said equipment, labor, tools, materials and appurtenances, together with the manner and time of furnishing the same, with delivery of all equipment no later than February 1, 2015. IT IS THEREFORE AGREED, first that a copy of said specifications and Proposal, submitted as aforesaid on the 29th day of October, 2014 be attached hereto and the same are hereby made the items and conditions of this agreement by and between the City and Contractor in all matters and things therein set forth and described; and further that the City and the Contractor accept and agree to the terms and conditions of said specifications and Proposal as submitted as completely as if said terms and conditions and plans are herein set out in full. In witness whereof the pa ies hereto hive caused this agreement to be executed the day and year herein above written day of 2014. CITY OF PASCO BY AT Approved as to form: s City Attorney BILFINGER WATER TE HNOLOGI C. BY: Contr c rsigure &) � 45d4 6.x(7 Contractor' Printed Name & Title (: `S (0 RESOLUTION NO. 3 5"'O 0 A RESOLUTION WAIVING COMPETITIVE BIDDING REQUIREMENTS FOR THE PURCHASE OF TWO (2) 17 MILLION GALLON PER DAY (MGD) BARREL SCREENS AND ONE (1) HYDROBURSTrm AIR CLEANING SYSTEM FROM BILFINGER WATER TECHNOLOGIES, INC., AND AUTHORIZING THE PURCHASE. WHEREAS, the existing Butterfield raw water traveling screen must be replaced with an alternate intake method, and WHEREAS, the City is now considering the purchase of an intake system similar to the one in use at the West Pasco Water Treatment Plant (WTP), and WHEREAS, the City has evaluated the performance of the proposed barrel screens and Hydroburstrm air cleaning system from Bilfinger Water Technologies, Inc., and found it capable of providing the Butterfield WTP with a reliable supply of raw water while meeting current Washington Department of Fish and Wildlife (WDFW) and National Marine Fisheries Service (NMFS) regulations, and WHEREAS, the purchase of barrel screens and a Hydroburst'm air cleaning system will allow the City to reduce the costs of operation, maintenance and repair at the Butterfield raw water intake facility, and WHEREAS, pursuant to RCW 39.04.280, Bilfinger Water Technologies, Inc., is the sole source of barrel screens and a HydroburstT' air cleaning system, capable of supplying the Butterfield intake facility while meeting current WDFW and NMFS regulations, thereby allowing the City to retrofit the non-compliant traveling screen; NOW THEREFORE, BE IT RESOLVED BY THE CITY COUNCIL OF THE CITY OF PASCO, that the City Council does hereby declare that the purchase of barrel screens and a HydroburstTM air cleaning system is clearly and legitimately limited to a single source of supply, and that the sole source of supply is Bilfinger Water Technologies, Inc., and BE IT FURTHER RESOLVED, that the competitive bidding requirements for the City of Pasco are hereby waived and the Pasco Public Works Department is authorized to purchase two (2) 17 MGD Barrel Screens and one (1) HydroburstTm air cleaning system from Bilfinger Water Technologies, Inc., for an amount not to exceed the sum of $122,500. PASSED by the City Council of the City of Pasco this 61h day of October, 2014. Matt Watkins Mayor APPROVED AS TO FORM: ian err Ci ttorney Submittals and Shop Drawings Submittal information, including shop drawings, are required for all items installed on this contract. Submittals shall be addressed to: City of Pasco 525 N. 3'd Avenue, P.O. Box 293 Pasco, WA 99301 Attn: Teresa Reed Jennings, P.E. Or: reed-jenningst@pasco-wa.gov Submittals may be provided in hard -copy or electronic format (preferred). Engineer reserves the right to require the Contractor to provide hard -copy submittals at no additional cost to the Owner. Where hard -copy submittals are provided, Contractor shall submit three (3) copies; one (1) set will be returned to the Contractor after review. Electronic submittal via email is acceptable; however the Contractor shall take responsibility to follow up with the Engineer to verify that the submittal was received. Neither the Engineer not Owner assumes responsibility for emails that do not make it to the recipient. Submittal data for each item shall contain sufficient information on each item to determine if it is in compliance with the contract requirements. Submittal cutsheets and datasheets shall be annotated by the Contractor and shall dearly indicate the equipment and materials that will be provided, including any options or additive items. No generic cutsheets or datasheets will be accepted. Items that are installed which have not been approved through the shop drawing process may at the discretion of the Owner, be removed and an approved product be furnished in its place, all at the Contractors expense. Shop drawing review will be limited to general design requirements only, and shall not relieve the Contractor from responsibility for errors or omissions, or responsibility for consequences due to deviations from the contract documents. No changes may be made in any submittal after it has been reviewed except with written notice and approval from the Owner. Shop drawings shall be submitted on 8'/2 -inch x 11 -inch, 11 -inch x 17 -inch, or 22 -inch x 34 -inch sheets and shall contain the following information: • Project Name as it appears on the Document Cover • Prime Contractor and Applicable Subcontractor • RH2 Engineering • Owner's Name • Applicable Specification and Drawings Reference \\nh2\dr.\Richland\Data\PSC\713-110\Specs\PSC - B'=ID - JOHNSON SCREENS.dou City of Pasco Winter 2014/2015 Butterfield WTP Intake Screen and Air Burst Systems • A stamp showing that the Contractor has checked the equipment for conformance with the contract requirements, coordination with other work on the job, and dimensional suitability • A place for the Engineer to stamp Submittals that do not comply with these requirements may be returned to the Contractor for re -submittal. Acceptable submittals will be reviewed as promptly as possible, and transmitted to the Contractor within approximately twenty (20) working days after receipt by the Engineer. Revise and submit as necessary. Delays caused by the need for re- submittal shall not be a basis for an extension of contract time or delay damages. Shop drawings and submittals shall contain the following information for all items A. Shop or equipment drawings, dimensions, and weights B. Catalog information C. Manufacturer's specifications D. Special handling instructions E. Maintenance requirements F. Wiring and control diagrams G. List of contract exceptions By approving and submitting shop drawings and samples, the Contractor warrants that they have determined and verified all field measurements, field construction criteria, materials, catalog numbers, and similar data, and have checked and coordinated each shop drawing with the requirements of the work and of the contract documents. The Owner will pay the costs and provide review services for a first and second review of each submittal item. Additional reviews shall be paid by the Contractor by withholding the appropriate amounts from each payment estimate. The Contractor is responsible for identifying the shop drawings and submittals required for this project. Items that are installed but have not been approved through the submittal process may be rejected and must be removed and replaced with an approved product at the Contractor's expense. Specific submittal requirements are listed in each section of these specifications. The Contractor shall keep a complete and current copy of all submittals and review responses at the job site readily available to the Engineer and Owner for inspection. \\ih2\dfs\Richland\Data\PSC\713-110\Specs\PSC - BTPRFLD -JOHNSON SCREENSAd City of Pasco Winter 2014/2015 Butterfield WTP Intake Screen and Air Burst Systems Equipment 11.00 GENERAL A. This division covers that work necessary for providing and installing all equipment as described in these specifications and as shown on the plans. 11.60 TREATMENT EQUIPMENT 11.63 Water Filtration Equipment 11.63.33 Automatic Self-cleaning Barrel Screens Part 1- General Summary A. Contractor shall provide all labor, materials, equipment and incidentals required to furnish and install the self-cleaning barrel screens, motors, system controls, and accessories. Submittals A. The barrel screen design, shop drawings, specifications, and calculations must be submitted to the owner for review and approval prior to fabrication. Screen diameter, screen length, assembly length, interface dimensions for outlet and air backwash dimensions, materials of construction, and assembly weight shall all be included. B. Shop drawings shall clearly indicate all shop and field fabrication sequences and assembly details. C. Contractor -initiated changes shall be specifically noted on the shop drawings and be submitted in writing to the Engineer for approval prior to fabrication or construction. Details of all welded joints shall be submitted for approval. D. Weld procedure specifications and welder certifications shall be submitted for review and acceptance prior to any field welding. All Welders must maintain certification to ASME Section IX. E. Evidence of a statistical control program. F. Provide flows through screens with screen centerline at the following depths below the water surface, and provide verification with physical flow distribution tests. a. Extreme high water level (351 feet) b. Normal water level (340 feet) c. Extreme low water level (335 feet) G. Provide headless information through a clean screen. H. Computational Fluid Dynamic (CFD) analysis and physical testing that verify intake screen capacities. \\rh2\dfs\Richland\Data\PSC\713-110\Specs\PSC - BTTRFLD -JOHNSON SCUENS.dou City of Pasco Winter 2014/2015 Butterfield WTP Intake Screen and Air Burst Systems Part 2 - Products Materials A. Screen cylinder mesh, end plate/cone, connection flange, air connection, and lifting lugs a. 304 stainless steel B. The main outlet flange shall mate with a 30 -inch flange pattern equal to AWWA C-207, Table 2, Class D. Quality Assurance A. The entire intake screen system shall be furnished by a single manufacturer. B. The intake screen must maintain an ongoing quality assurance program, including ISO - 9000 certification. C. Supplier shall have proof of at least one -hundred (100) installations and at least ten (20) years experience manufacturing equipment of similar technology. Design Requirements A. Barrel screens are to be tee style with an air backwash connection. B. Individual screen capacity shall be a maximum of 12,500 gallons per minute with the screen centerline 18 feet below the water surface. a. Total intake assembly capacity of 25,000 gpm with the screen centerline 18 feet below the water surface shall be met by two intake screen assemblies. C. Pressure drop through the entire intake screen assembly shall be no greater than 0.67 psi at the rated flow. D. Maximum screen mesh opening dimensions a. 3/32 -inch (diagonal); and b. 0.067 inches x 0.067 inches (square) c. The mean screen size opening shall be within +/- 0.002 -inches with a standard deviation no greater than 0.002 -inches throughout the assembly. d. Screen opening size shall be controlled and continuously monitored during manufacture. E. Wire mesh thickness shall be #69 wire (0.071 inches) a. Wire mesh, support beam and stiffener structure shall be an all -welded matrix designed to provide the specific strength with minimal interference with the through screen flow pattern. F. Maximum approach velocity shall not exceed 0.40 feet per second at the design capacity. G. The upstream end of each barrel screen shall have a conical deflector, and the downstream end shall have a dished head. \\rh2\dfs\Richland\Data\PSC\713-110\Specs\PSC - B=LD -JOHNSON SCREENS.docx City of Pasco Winter 2014/2015 Butterfield WTP Intake Screen and Air Burst Systems a. End plates and tee body shall be a minimum of 0.105 inches thick. All structural butt welds shall be full penetration fillet welds and shall be the thickness of the thinner component. H. Intake assembly shall be designed to a maximum of 5 psi negative pump pressure or differential headloss. a. Design stress used for determining strength of the assembly shall be no more than 90 percent of the published yield strength of the material used. Strength calculations verifying compliance with these criteria shall be provided upon request. I. System source water is the Columbia River. J. System operating temperature is 30°F to 70°F. K. Power source is 480 VAC, 3-phase, 60 Hz. L. Barrel screen assembly shall be equal to Johnson Screens T42HCE. Substitutions A. Manufacturers other than that which is specified and/or not meeting EVERY provision of the specification shall be required to submit a complete and detailed PRE - QUALIFICATION PACKAGE to the engineer at least (15) days prior to the bid. Any PRE -QUALIFICATION PACKAGE must contain as a minimum: a. Detailed layout drawings. b. Supporting flow distribution data via a CFD (Computational Fluid Dynamics) analysis. c. Weld certifications. d. Evidence of a recognized ongoing quality assurance program. e. Detailed component specifications and catalog cuts as required. f Detailed list of ALL VARIATIONS required from the original design, referencing appropriate sections of the specifications and locations on the drawings. g. Full installation reference list of at least (50) customers that includes similar proposed equipment. B. Manufacturers qualifying will be recognized by addendum issued a minimum of five (5) days prior to the bid. Contractors shall include all costs associated with any redesign required with their bid. C. Manufacturers not meeting this specification in EVERY WAY or are not PRE- QUALIFIED and approved by the Owner will not be considered for use in this project. Part 3 - Execution Materials A. The Contractor shall provide tools and equipment, including any special tools required for installing each particular type of pipe used. \\rh2\dfs\Richland\Data\PSC\713-110\Sracs\PSC - BTTRTLD -JOHNSON SCREENS.dou City of Pasco Winter 2014/2015 Butterfield WTP Intake Screen and Air Burst Systems B. Barrel screen shall be connected to inlet piping and air burst backwash line on land, and inspected by owner. Following owner approval, the barrel screen and piping can be installed in the river. The contractor shall install the concrete anchor prior to backfilling the pipe and trough. 11.94.22 Air Burst Systems Part 1- General Summary A. Provide an air burst backwash system consisting of compressor, piping, valving, instrumentation and controls necessary to provide a sufficient amount of air to backwash the two intake screens as specified herein and as shown on the drawings. A receiving tank shall be provided and the air burst backwash system shall be mounted on top of the receiving tank. The backwash air shall scour the screen surface to maintain adequate design flow and approach velocity characteristics. Related Sections A. See Section 5.05 — Structural Connectors and Concrete Anchors B. Section 11.63.33 —Automatic Self-cleaning Barrel Screens Submittals A. Submit shop drawings, manufactures data, pertinent literature, and installation instructions and requirements prior to manufacturing. B. Air Burst System: Submit drawings or literature showing receiver size, piping size, valve literature, compressor manual, electrical schematic, control system schematics and requirements, installed dimensions and weight, and installation instructions and requirements. An electronic version of the O&M manual shall be provided. a. Submit drawings, manufactures data, pertinent literature, and installation instructions for air burst pipe spacers. Operating Requirements A. All components shall arrive on-site and be ready to operate without field assembly. All interconnecting wiring between the compressor, bursting equipment, receiver, and screens shall be completed on-site. B. The air compressor system shall operate in both manual and automatic mode to deliver compressed air to the air burst system for cleaning the intake screens. The air burst system shall deliver a controlled burst of high pressure air to each individual barrel screen by automatic or manual control. A local control panel shall be located on top of the receiving tank for controlling and monitoring the compressor unit in both manual and automatic modes. A timer shall be furnished and installed to operate the compressor unit in automatic mode. The timer's intervals shall be capable of hourly, daily, or weekly burst cycles. In the case of the shared wet well, the system shall be designed to clean the upstream screen first followed immediately thereafter, upon recovery of sufficient air volume in the receiver tank, by the second screen. The system shall ensure that both \\rh2\dfs\Richland\Data\PSC\713-110\Specs\PSC - BITRFLD - JOHNSON SCREENS.dou City of Pasco Winter 2014/2015 Butterfield WTP Intake Screen and Air Burst Systems screens of a single shared wet well are cleaned in succession, regardless of the reduction in water level differential achieved upon cleaning of the first screen. Each zone of the air burst system shall correspond to each screen with a dedicated wet well or each pair of screens that share a wet well. A receiver tank shall be furnished for storing sufficient air for actuating one zone of the air burst system. C. Operation: The compressor shall have three modes of operation: Hand — Off — Auto 1. Hand (Load/Unload) Mode: With the control panel mode switch in the "Hand" position the system shall operate as follows: The compressor shall start and run until the shut-off pressure switch set point is reached. When the proper pressure point is reached (as indicated by the high-pressure switch) the unit shall automatically stop. The unit shall stop any time the mode switch is placed in the "Off" position. 2. Auto (Start/Stop)Mode: With the control panel mode switch in the "Auto" position the system shall operate as follows: The air compressor shall operate automatically to recharge the air receiver any time the pressure control switch falls below the minimum pressure set point. When the pressure in the receiver tank falls below the minimum pressure set point the compressor shall automatically start and run until the maximum pressure set point is met and the compressor shall then automatically stop. The pressure control switch shall have adjustable differential between the high-pressure stop point and the low- pressure start point. The unit shall stop any time the mode switch is placed in the "Off' position. In auto mode, the system shall be required to have permission from the telemetry system, via the EtherNet/IP connection, to run in addition to the receiver pressure switch. D. Alarms: The following alarm conditions shall automatically stop the compressor and illuminate an indicating light: • Low oil level • Low oil pressure • High oil temperature • High air pressure E. An alarm reset pushbutton shall be furnished for acknowledging and clearing the alarm lights. Warranty A. The manufacturer shall provide a two year warranty, from the date of substantial completion, against defects in workmanship and materials. Substantial completion shall be no later than 6 months after screen and air burst system start up. Quality Assurance A. Air Burst System: System shall be supplied by an ISO 9000 Certified company, fabricated by ASME Section IX Certified welders and the manufacture shall provide evidence of \\ih2\dfs\Richland\Data\PSC\713-110\SPccs\PSC , BTIRFLD -JOHNSON SCREENSA.. City of Pasco Winter 2014/2015 Butterfield WTP Intake Screen and Air Burst Systems experience in having supplied at least 25 assemblies of similar designs which have been in successful service for at least 10 years. Part 2 - Products A. Compressor: Reciprocating type, 15 hp splash lubricated air compressor shall be furnished. The air compressor shall have sufficient capacity to recharge the receiver from an operating pressure 0 psi to 125 psi in less than 15 minutes. A 2 -year warranty shall be provided on compressor parts. Compressor shall be equipped with a low oil level switch. The compressor shall operate on 460vac, 3 phase, 60 hertz. The compressor shall be manufactured by Saylor -Beale or approved equal. Compressor shall be mounted on the receiver. The compressor shall be used to charge both the primary and auxiliary receivers. B. Receiver: A 620 gallon, horizontal grasshopper style, ASME coded 200 psi receiver with a 4 -inch isolated pressure gauge, pressure switch, safety valve, and automatic drain shall be provided. The receiver shall be sized to displace three screen volumes of air at the screen during a backwash to provide suitable debris removal and cleaning. Two of three volumes shall be delivered in the first one (1) second of the backwash cycle. C. Air Burst PipePipe: A 4 -inch diameter HDPE DR17 pipe (4.5 -inch outside diameter) shall be provided for the air burst pipe. The pipe shall be provided with spacers installed per the manufacturer's recommendations, and shall be cased in a Schedule 40 steel pipe. Spacers shall be Calpico P -SS or Owner -approved equal. D. Operation: The system shall operate in MANUAL or AUTO mode. In manual mode the backwash for each valve shall be initiated by a pushbutton, provided the system is powered and the system has adequate air pressure. In the AUTO mode the air burst cycle is initiated by the automatic timer. Upon backwash commencement, the first valve will open and remain opened for a programmed period of time. In the MANUAL mode the backwash is initiated by a push button. \\rh2\dfs\Richland\Data\PSC\713-110\Specs\PSC - BTIRFLD -JOHNSON SCREENS.d= Bilfinger Water Technologies, Inc. 1950 Old Hwy 8 NW New Brighton, MN 55112 Tel no: 1-800-833-9473 Fax no: 651 - 638 - 3132 QUotltiofl Number/Date 20006216 / 10/29/2014 Reference no./Date Pasco, WA Sold -To 10004012 Validity period 10/29/2014 to 12/29/2014 Sales person name Mark Watson Entered by Linda S Cook to the following conditions: Currency USD Terns of payment: Within 30 days without deduction Terms of delivery: FCA New Brighton, MN Shipping conditions: US: Prepaid Item Material Qty UOM Price Value Description 000010 2.000 EA 23,600.00 USD 47,200.00 Johnson T-42HCE Intake Screen T-42 High Capacity Extended Intake Screen Wire: #69 Slot: .067' Material: 304 stainless steel Air Backwash Connection: 4" Flow: 12,500 GPM/ Screen has under .4 ft/sec max approach slot velocity Depth: 18 Ft Outlet: Flange pattern to match AWWA C-207 class D 30" with outlet pipe. End Closures: Endplate X End Cone 000020 1.000 EA 51,200.00 USD 51,200.00 Johnson Hydroburst System Tank mounted compressed air system designed for Doc. no./Date Page 20006216 / 10/29/2014 2 Item Material Qty UoM Price Value Description indoor operation, with all components mounted, piped and wired and consisting of the following: Saylor -Beall 15HP tank mounted, splash lubricated, reciprocating type air compressor with a capacity of 61.2 ACFM @ 175 PSIG and furnished with: - 15HP ODP, 3/60/460V high efficiency electric motor. 1.15 SF - OSHA style, totally enclosed belt guard - Auto start -stop pressure switch, NEMA 4X - Low oil level shutdown switch - 10 micron inlet air filters - Factory fill of synthetic lubricant - 660 gallon ASME coded, 200 PSIG MWP, horizontal air receiver with safety valve, pressure gauge, float type auto drain, vibro isolator pads and two (2) 4" size side mounted flanges. - Two (2) 12" long ss flex discharge hoses with 4" flanges. NEMA 4X dual pressure switch for system air pressure pilot light actuation and butterfly valve control. NEMA 4X high pressure switch. NEMA 4 steel control panel to operate one 15HP compressor and two (2) 120VAG solenoid valves on 460V 3PH service for manual, automatic timer control or remote actuation of the air backwash system. The control panel is supplied with: - U/L label - Main circuit breaker - Motor starter - Overload reset push button - Set primary transformer fuses - Control transformer - Two (2) control circuit breakers - System off -on selector switches - Power on pilot light - Test -off -auto selector switch - Run pilot light - Overload alarm pilot light - Low oil level alarm pilot light - Low air pressure alarm pilot light - High air pressure pilot lingt - Adequate air pressure pilot light - 7 day programmable timer Doc. no./Date 20006216 / 10/29/2014 Page 3 Item Material Qty UoM Price Value Description - Cycei start push button - Cycle in progress pilot light - Two (2) valve open -close -auto selector switches - Two (2) valve open pilot lights - Two (2) valve closed pilot lights - Remote start terminals - Auxialiary contact provided for all alarms and functions Control air receiver, ASME coded 200 PSIG MWP, with inlet check valve, pressure gauge, safety valve, filter/regulator with gauge and manual drain valve. Two (2) 4" size lug style butterfly valves, 225 PSIG MWP, with ductile iron body, stainless steel disc and stem, EPDM seat and seals, spring return pneumatic actuator, NEMA 4X solenoid valve with manual override and NEMA 4X position indicator with mechanical limit switches. The above components mounted, piped and wired on the 660 gallon horizontal air receiver. Receiver dimensions: 42" diameter X 117" long Calculated recharge time: 50-150 PSIG in 12 minutes Bilfinger Water Technologies Intake Screens are covered by one or more of the following patents - #6,051,131; #6,712,959; #8,297,448; and other patents pending. SHIPMENT ON INTAKES: 2-3 Wks for drawing submittals 6-8 Wks after drawing approval, subject to manufacturing capacity SHIPMENT ON HYDROBURST: 3-4 Wks for drawing submittals 14-16 Wks after drawing approval, subject to manufacturing capacity Items total 98,400.00 Tax Jur Code Level 1 0.000 98,400.00 0.00 Final amount 98,400.00 Bilfinger Water Technologies, Inc. 1950 Old Hwy 8 NW New Brighton, MN 55112 Tel no: 1-800-833-9473 Fax no: 651 - 638 - 3132 BiLFINGER Number/Date 20005105 / 09/15/2014 Reference no./Date Pasco, WA Sold -To 10004012 Validity period 09/15/2014 to 11/17/2014 Sales person name Mark Watson Entered by Linda S Cook Ne deliver according to the currency ubu Terms of payment: Within 30 days without deduction Terms of delivery: FCA New Brighton, MN Shipping conditions: US: Prepaid OBSOLETE Item Material Qty UoM Price Value Description 000010 2.000 EA 24,500.00 USD 49,000.00 Johnson T-42HCE Intake Screen T-42 High Capacity Extended Intake Screen Wire: #69 Slot: .067" Material: 304 stainless steel Air Backwash Connection: 4" Flow: 12,500 GPM/ Screen has under .4 ft/sec max approach slot velocity Depth: 20 Ft Outlet: Flange pattern to match AW WA C-207 class D 36" with outlet pipe End Closures: Dished Head X End Cone HYDROBURST SYSTEM: Based on an air line distance of 150 feet and a screen depth of 20 feet you would need a 620 gallon air receiver tank with 4" air lines. Doc. no./Date 20005105109/1512014 Page 2 Item Material Qty UoM Price Value Description Standard System: Price of $45,000.00 System would include the following - 620 gallon ASME coded for 200 PSIG MWP -15 HP splash lubricated reciprocating type compressor with motor starter - Two (2) 4" lug style butterfly valves with a 225 PSIG MWP, spring return to close pneumatic actuator, single solenoid control valve with manual override and position indicator with mechanical limit switches. - Control panel for manual, automatic timer controlled or remote actuation of the air backwash system. PLC System: Price m $70,00nclu L E System would include folio Vard /"7 Same as above except L - Control panel would incl a stL Bilfinger Water Technologies Intake Screens are covered by one or more of the following patents -#6,051,131; #6,712,959; #8,297,448; and other patents pending. SHIPMENT ON INTAKES: 2-3 Wks for drawing submittals 6-8 Wks after drawing approval, subject to manufacturing capacity SHIPMENT ON HYDROBURST: 3-4 Wks for drawing submittals 14-16 Wks after drawing approval, subject to manufacturing capacity Items total 49,000.00 Tax Jur Code Level 1 0.000 49,000.00 0.00 Final amount 49,000.00 Dished Value Unit Comments Head End T42HCE Lifting Lugs Optional (Used on Flat Plate as Required 9 Conical Debris Larger End in Nominal See note i Deflector Screens) in Nominal See note 1 Outlet Connection Size 36PS Sea note 2 ABW Connection Size 4PS See note 2 Estimated Weight 2300 has Left End Closure Dished jjj i I Care OD — C� An" Location and D ABW Al geometry of ABW q1 flange can be changed to match installation Flan requirements. Q conte OBSO Cylinders to match class D ge bolt holes stradle nines unless otherwise specified LETE Dimelrelon/Sizes Value Unit Comments Model T42HCE LID Ratio 1.050 OD 42.00 in Nominal See note 1 DAL 152.00 in Nominal See note i CL to Flange 42.00 in Nominal See note 1 Outlet Connection Size 36PS Sea note 2 ABW Connection Size 4PS See note 2 Estimated Weight 2300 has Left End Closure Dished [Right End Closure I Care Screen Specifications Slot Opening 0.067 fin Open Area Percentage 48.55% LID Ratio 1.050 Effective Screen Length 44.25 lin Wire Type 69 Dasi n• OZ—111h' 1 20 lFt 111-lydrostatic Load lCollepse Rating 8.67 [psi I Material 304 SS or Z-Aloy Flow Capacities; Flow/Screen 12500 GPM See note 3 Maximum Slot Velocity 0.40 fps Approach Slot Velocity Average Slot Velocity 0.36 fogroach Sbt Velodt Estimated DP/Screen 0.0093 psi Thm dean ween sudace only -See note 4 Estimated DP/Assy 0.5398 psi Through entire clean assembly - See note 4 Notes: 1 Dimensions shown are nominal. AN screens are made to order, and can be adapted to a wide variety of installation requirements. 2 These are based on the sae of the connecting and sow pipe and may vary from the values listed In the technical brochure. 3 Capacities basad on use of patented Johnson sow modifier design. 4 Pressure drops below .1 psi should De considered an order of magnitude only, as tailing dale for mese low values is not available. KA 1950 MN 55112 PATEN'[ # #6,051,131 The concepts and assemblies shown should be considered proprietary and should not be copied, redistributed without the permission of US Filter/Johnson Screens. All dimensions are preliminary, changes may be made and can effect final price and configurati Model T42HCE Preliminary Intake Screen Specification Pasco, WA Date: 9 BILFINGER WATER TECHNOLOGIES, INC. BiLFINGER CREDIT APPLICATION FOR A BUSINESS ACCOUNT BUSINESS CONTACT INFORMATION Title Ahmad Qayourni, Public Works Dir. Date business commenced 1891 Company name City of Pasco WA 0 Sole proprietorship t Phone I Fax l 509.545.3446 1/509.543.5737 0 Partnership E-mail CIAYOUMIA@pasco-wa.gov Z Corporation Registered company address PO Box 293, 525 N. Third Avenue 0 Other City, State ZIP Code Pasco, WA 99301 BUSINESS AND CREDIT INFORMATION City, State ZIP Code Pasco, WA 99301 Bank name: U.S. Bank How long at current address? 19 years Primary business address PO Box 293,525 N. Third Avenue City, State ZIP Code Pasco, WA 99301 Phone ti 509 545.3446 Phone 509.545 3444 Fax 509 543.5737 Account number I E-mail Type of account DSavings 0 Checking 0 Other Company name -BU-S.I.NESS-/TRADE.R.EF.EREN.C.E.S.--. Franklin PUD Phone ---- -- - 500"!9.547.5591 Address PO Box 2407 Fax 5 W9.547.4116 City, State ZIP Code Pasco, WA 99302 E-mail kfulton@franklinpud.com Type of account Other Commercial Company name TriCity Herald Phone 509.582.1483 Address 333 W. Canal Drive Fax 509.582.1488 City, State ZIP Code Kennewick, WA 99336 E-mail Bwineland@tricityheraid.com Type of account Other i Legal/Classified Company name BDI Phone 509.547.2476 Address PO Box 3850 Fax 509.547.8617 City, State ZIP Code Pasco, WA 99302 E-mail laurel@basindisposal.com Type of account Other Commercial AGREEMENT 1. Customer agrees to Bilfinger's Terms and Conditions of Sale. 2. All invoices are to be paid 30 days from the date of the invoice unless otherwise agreed in writing by the parties. Past due accounts are subject to interest at the maximum rate allowed by law. 1 Claims arising from invoices must be made within seven working days. 4. By submitting this application, you authorize BILIFINGER WATER TECHNOLOGIES, INC. to make inquiries into the banking and business/trade references that you have supplied. SIGNATURES Signature -A Signature Name and Title Ahmad Qayoumi, Public Works Director I Name and Title 4AIMLFinance Manager I Date October 29, 2014 Da June 2014