Loading...
HomeMy WebLinkAbout4401 Resolution - Change Orders 22-27 LSORESOLUTION NO.4401 A RESOLUTION OF THE CITY OF PASCO, WASHINGTON, AUTHORIZING THE CITY MANAGER TO EXECUTE CHANGE ORDER NOS. 22-27 TO THE CONSTRUCTION CONTRACT WITH CASCADE BRIDGE, LLC. FOR THE LEWIS STREET OVERPASS PROJECT. WHEREAS, the City of Pasco, Washington and Cascade Bridge, LLC. entered into a Construction contract on March 1, 2021, for construction of the Lewis Street Overpass Project; and WHEREAS, this project involves the construction of a new 562-foot, 4-span, pre -stressed Concrete overpass, over the BNSF Railway yard and a new 63-foot, voided slab, overpass over First Avenue. Along with roadway improvements, backfilling, partial structure removal, retaining wall construction, earthwork, paving with HMA, landscaping, storm drainage, illumination, water mains, sanitary sewer, and other associated work; and WHEREAS, the City of Pasco, Washington and Cascade Bridge, LLC. executed Change Orders Nos. 1 through 21 to provide for additional work not included in the original contract; and WHEREAS, proposed Change Orders Nos. 22 through 27 involve additional work related to: BNSF Security Fence, BNSF Bridge No. Signs, Modified BNSF Water Service, SEW Wall Design Revisions, and Traffic Control items and temporary barrier for a total of $1,774,244.93; and WHEREAS, the City Council of the City of Pasco, Washington, has after due consideration, determined that it is in the best interest of the City of Pasco to enter into Change Order Nos. 22-27 with Cascade Bridge, LLC. NOW, THEREFORE, BE IT RESOLVED BY THE CITY COUNCIL OF THE CITY OF PASCO, WASHINGTON: That the City Council of the City of Pasco approves the terms and conditions of the Change Order Nos. 22-27 between the City of Pasco and Cascade Bridge, LLC. as attached hereto and incorporated herein as Exhibit A. Be it Further Resolved, that the City Manager of the City of Pasco, Washington, is hereby authorized, empowered, and directed to execute said Change Order Nos. 22-27 on behalf of the City of Pasco. Be It Further Resolved, that this Resolution will take effect immediately. Resolution — CO 22-27 for Lewis St Overpass - 1 PASSED by the City Council of the City of Pasco, Washington, on this 20'h day of November, 2023. Blanc a Ba Mayor ATTEST: &c4,A-- Debra Barham, CMC City Clerk Resolution — CO 22-27 for Lewis St Overpass - 2 APPROVED AS TO FORM: Kerr son Law, PLLC CiqAxttomeys EXHIBIT A CITY OF PASCO I li*A f PUBLIC WORKS DEPARTMENT CONTRACT CHANGE ORDER NO. 22 �I X Standard ❑ Unilateral Project No: Project No: 13007 Project Title: Lewis Street Overpass FED -AID #: STPUS-HLP-3530(006) WSDOT: TA4087 Contractor: Cascade Bridge LLC Reason for Change: BNSF Security Fence Detail as Appropriate: This change order creates a force account pay item to reimburse the contractor for the costs of renting, placing, and maintaining security fencing per BNSF direction. Contract Bid Amount: SALES TAX Q 8.6%: Total: $22,344,999.88 1 22,344,999.88 PREVIOUS CHANGE ORDER CURRENT CHANGE ORDER Subtotal $1,918 499.66 Subtotal $ 20 000.00 Sales tax (rate varies) $17 296.43 Sales tax ® 8.9%. Total $1,935,796.09 Total $ 20,000.00 Total Change Orders To Date $ 1,955,796.09 New Contract Amount IS CONTRACT TIME AFFECTED BY THIS CHANGE ORDER Contract Time Prior to this Change Order ................................. Modification to Contract time by this Change Order .................... Revised Total Contract Time .................................................... $ 24,300,795.97 460 0 460 NO It is mutually agreed by both parties that this Change Order fully describes the change(s) that is (are) being made and that the compensation for this Change Order is full and complete and is the only compensation due or owing for this Change Order. Further, it is mutually agreed that this document will supplement the present Contract Documents and that the provisions of the previously executed Contract Documents shall apply to this Change Order. ®REP 7PTED:/ ROVED: -2 8/29/23 CT Date PROJECTMANAGER Data PROVED: APPROVED: CONST. MANAGER Dale CIP MANAGER Date PUBLIC WORKS DIRECTOR Date Add the Following Bid hems: Bid Item: A-186 BNSF Security Fencing 1 LS $ 20,000.00 Sales Tax 8.9% Subtotal, Additions ............................................... Total this Change Order ............................................... $ 20,000.00 CITY OF PASCO PUBLIC WORKS DEPARTMENT CONTRACT CHANGE ORDER NO.23 X Standard [] Unilateral Project No: Project No: 13007 Project Title: Lewis Street Overpass FED -AID #: STPUS-HLP-3530(006) WSDOT: TA4087 Contractor: Cascade Bridge LLC Reason for Change: BNSF Bridge No. Signs Detali as Appropriate: This change order adds one new item, A-187 BNSF Bridge No. Signs. This item shall be full compensation for all materials, tools, and equipment necessary to provide and install two bridge number signs as shown on new plan sheet SS-2 (attached). Contract Bid Amount: SALES TAX @ 6.6%: Total: $22,344,999.88 $ 22,344,999.68 PREVIOUS CHANGE ORDER CURRENT CHANGE ORDER Subtotal $1 938 499.66 Subtotal $ 1,855.51 Sales tax (rate varies) $17,296.43 Sales tax Q 8.91A Total $1,955,796.09 Total $ 1,855.51 Total Change Orders To Oata $ 1,957,651.60 New Contract Amount $ 24,302,651 AS IS CONTRACT TIME AFFECTED BY THIS CHANGE ORDER NO Contract Time Prior to this Change Order ................................. 460 Modification to Contract time by this Change Order .................... 0 Revised Total Contract Time .................................................... 460 It is mutually agreed by both parties that this Change Order fully describes the change($) that is (are) being made and that the compensation for this Change Order is full and complete and is the only compensation due or owing for this Change Order. Further, it is mutually agreed that this document Will supplement the present Contract Documents and that the provisions of the previously executed Contract Documents shall apply to this Change Order. E T A CEPTED PROVED: Z5 Z 2, 8/29/23 T Dab PROJECT MANAGER Dale PROVED: APPROVED: CONST. MANAGER Date CIP MANAGER Date PUBLIC WORKS DIRECTOR Dab Add the Following Bid Items: Bid Item: A-187 BNSF Bridge No. Signs 1 LS $ 1,855.61 Sales Tax 8.9% Subtotal, Additions ............................................... Total this Change Order ......••••.•...•...••••.•..••...........••.•..• b 1,855.51 f,� S BRACKET BRACKETS S BARRIER COLUMN BARRIER COLUMNS m 6 6 z 5.5 SEE BRACKET DETAIL ITYP.) W moo 711E W N L O a -lr z m L�WVIS ST. OVER 'SS S W 3 WrO HOLE.TYP. j o N = aLL J.T. N0. 9 7780 BRACKETS „)d) BARRIER COLUMNS F Y 1 3.5 10.6 3 4.9 3 19.6 3.5 4. 1 9.3 1 31 5.8 13 1 17.6 4.648 n j TYPj �R� I I X 1 I 2.0" RedI., 0.5" Border, 1.0" Indent Bkck - WNRe; CAST M PLACE 11/2"0 x LONG R �_ � GALVANIZED GALV.OR. A36 THREADED ROD WI -- PL 10"X6"XIW 4X�Yf "LEWIS ST. OVERPASS" White, D 2K; 3.5" EMBEDMENT. SEE NOTE <, TYP.n€U "O.O.T. NO. 97780OL" White, D 2K; 3" 3" �bS�1 LEWIS ST OVERPASS DOT SIGN BRACKET DETAIL g ATTACH TO OUTSIDE FACE OF PEDESTRIAN BARRIER Rlln SIGN PLACEMENT DETAIL NOTES: 1. INSTALL THE LEWIS ST OVERPASS DOT SIGN ON THE OUTSIDE OF THE PEDESTRIAN BARRIER DIRECTLY OVER MAIN TRACK 3. 2. APPROXIMATE STATION OF MAIN TRACK 3 AT THE NORTH EDGE OF BRIDGE IS 22-20. 3. APPROXIMATE STATION OF MAIN TRACK 3 AT THE SOUTH EDGE OF BRIDGE IS 22v12. 4. MOUNT SKIN WITH GALV.LOCK WASHER AND HEX NUT. ENSURE ADEQUATE LENGTH OF THREADED ROD PROTRUDES TO ACCOMMODATE MOUNTING HARDWARE. Z 0 yZ aGo Ui W3 0 rn a wo J T SS-2 CITY OF PASCO PUBLIC WORKS DEPARTMENT r. CONTRACT CHANGE ORDER NO.24 X Standard ❑ Unilateral Project No: Project No: 13007 Project Tide: Lewis Street Overpass FED -AID #: STPUS-HLP-3530(006) WSDOT: TA4087 Contractor. Cascade Bridge LLC Reason for Change: Modified BNSF Water Service Detail as Appropriate: This change order adds one new item, C-081 Railroad RPBA 8 In. This item shag be full compensation for all materials, tools, and equipment necessary to provide and install the BNSF RPSA as shown on revised plan sheets RD-4, WS-4, WS-7, WSD-1, and information sheets for the Safe-T- Cover enclosure, eMchicai riser, and junction box (attached). Also attached to this change order for reference is a cut sheet for the Neptune Mach 10 water meter which will be provided and installed by the City of Pasco. The detail for the Railroad Water Service now includes two valves, and the RPBA requires an upstream valve. Therefore, the quantities of Eld Item C-024 Cate Valve 8 im will be increased by two (2) for the added valves. Bid Item C-056 Railroad Water Ser Ace 8 in. will be maintained as bid. Contract Bid Amount $22.344,999.88 SALES TAX @ 8.61A: — - Total: ; 4344,999.80 PREVIOUS CHANGE ORDER CURRENT CHANGE ORDER Subtotal 51.940 355.17 Subtotal _; 130.690.00 Sales tax (rate varies) $17296A3 Saks tax @ 6.2% S i i 631.41 i+stat _ 1.957.651.60 Total _ 3 142,321.41 Total Change Orders To Date ; 2,0N,9T3.01 New Contract Amount ; 24,444,972.89 IS CONTRACT TIME AFFECTED BY THIS CHANGE ORDER Contract Time Prior to tMs Change Order. ................................ _ 460 Modification to Contract time by this Change Order .................... 0 Revised Total Contract Time .................................................... 460 m it is mutually agreed by both parties that this change order fully describes the change(s) that Is (are)betrg made and that the compensation for this Change Order Is full and complete and is the only compensation due or owing for this Change Order. Further, it is mutually agreed that this document will supplement the presets Contract Documents and that the provisions of the previously executed Contract Documents shall apply to this Change Order. APPROVED: DPR6JECTMANAGER Date APPROVED: APPROVED: CON8T. MANAGER nets CP MANAGER Dane ..... PUBLIC WORKS DIRECTOR nets -. - - Add the Following Bid Items: - Bid Item: C-061 Rafted RPeA 8 h. 1 LS $ 126,690.00 C-024 Gate Vat" 8 kl. 2 Each $ 3,8W.00 Sales Tax 8.9% Subroral, Additions .............................................. S 11 a41 11 S 130,690.00 Total this Change Order..................................1............ ; 142,321A1 POINT! G I STATION !OFFSET 4. 1 Ines rm 3 1 L 24.4129 1.16 L 4 L 24V .4D IR L s Ln � 35:T7S4 SEC._29 T.9N. R.30E. W.M. FRANKLIN COUNTY 1 I I--- - -----' CIARK STREET Zac^s o Z UN� J.I m 3 LL Lu D 20 40 j m 2\ 1 I 1 1 j' , �...� SCALE IN FEET Y NOTE:' I''h_� '_3EC• 5 p ELECTRICAL DESIGN IS BASED ON THE ENCLOSURE YODEL AND HEATERS SHOWN ON a L,� 1UNCTbN BOX ��kv WS61. IF ENCLOSURE MANUFACTURER OR MODEL CHANGES. NOTIFY ENGINEER TOPOLEr� f^VERIFY ELECTRICAL SERVICE I Y'i1TY XFMR I 7 SS r CND.4A1D, - 4 PSA HEATED-tYtO GND �. S6 ' - I I COMBINATION UTILITY- ENCLOSURE LOCATION- 1 .ti`- METER /SERVICE PANEL �� -'a - - •_ _ _ _ ._ ._ �- w ••per GI- G-_ p__ p._-G-_ p _ G- 0- •N i lW--4W^F^W--- —N--•1'�ri-- .W—w—w."MTW -11L • '"—W"—W—W—W—W— W r 1 I -- ` , r"'? ------------- w -0 1 3" SPA. 4 i 1 L PC 24.76.1' . -1 Y CC u IliM fT 1 ' 2$1 MTD'bI11z I 1 F� I 4TAI/V1k& WALL I ' I 7 j I INSTALL VAULTS (2) E ' CONTRACTOR INSTALL ' I i URL SUPPLY PIPE f 21'10 FPUD. n __ _....._._.._._._ ..... _._.._._..._.__.._._.._... d8 (t�(19'�JCI LEWIS TY° �_�-._.__._: ar ar Ae-- - r-r�R-s r-. sr -aas,� mar -Ar -AP-'fir' W "M26c W W—W—W—M�Sw—M EM"�.Nl' �• - ----14Y_- NTo°Ds`1i �GP— -�---- -�-"--H='-s�=po;_------'➢Ft-----��,=-cr-`�=—F--'--H i y ;)SEE UP PLANS FOR LrRLUITY CONDUIT CONSTRUCTION, Y-O{i_ b ------f---------------------------------- ------- F� --r-'-- - ------------ SEE UNDERPASS PREPARATION PLANS ' l"IkAfF'IMM.§Tri"6N I x DETAILS THROUGH EXISTING UNDERPASS x z O I- RD-4 SEC. 29 T.9N. R.30E. W.M. mANKUN COUNTY RESTRAINE0JOINTPPE t`R1-- AND FITTWOS FROM RP9A TO 'II LF 1 EAST OF WATER METER VAULT 4 L21. ,43'LT TO L25.3], 65'LT O 220 4 M -2 I SCALE 0] 3 I f_-�y"•"�'vv'vv"i^"'v"vvv•/'.r''r�ra.1"4^xr+ � � N FEET , e i EXIST. LOW AREA i 1 : >� NOTE: 1 I ONSP RAILWAY w I P INV EL. 375.94 1 �~, I W SEE GENERAL WATER AND Y REORAOE TO L._..__ __- - - 1 FI SEWER NOTES ON L 2N39.59, 57 -LT 1 ' EL: 779.1s 195 CY3)1 t - I - 1 I WATER A SEWER .yS xLAN 1 I 1 8" d "THRUST T BEND I ,r. "•+Y`*"a' - `1 4W THRUST BLOCK I I �✓2 R F.T.. ,tl. - B' VERiSCEIE R TI 'i SEE DETAIL B- I:�:,t ' 1DHORI2. CLEAR `r 1 j INV EL: RJ (S) I ) f L N.71.68, WATER (CENTER I VAULT) B' FLrMJ OV "RJ ($) I{( 1 RIULROAD WATER OPSTSERVICE 6 G B' WATER METER BEET VJ&] 1, �J y, L 26-12.57, B3,57 LT i; B" RFCA (E) , I 1 PNO VAULT PER COP 5T0 DWG W.I. FQ PRECAST 1 ', I•, `�+ RETAIN AND PROTEC EXIST. SSMH r� ]x 57T VAVLT OR EQUAL ORIENTED AS SHOWN. PPE) �' .. 1 1 I r tt D.I.P WA, Is277LF1 bre.i�.• 1 ,{ C-.'• r L 24.39.��41.56'LT %� 1 jj '. y� PLUG EXIST. SEWER PIPE (SOUT!✓J ya A2 MM. LAVER >nAnt f. 1 PENETRATIONS TO BE GROUTED. -J" x 8'0.PBA PER COP SIG OWL(' Wte I RBA EL:3'79.6i •j r 8'O.I.P 617E (J2001F) ', 1 ) x• 1 i AS MODINED ON SHT W50.1 1 M{ I B" N9l M4V EL 374.50 - j W 42' MIN. COVER. `I CV W RJ (l 21.76.96, 5444' LT) �• 1 DEFLECT PPE JOINTS• I Ty.-z x- -y- 8'MJXMJ04 WRJ 21. _ II { . k ,...•. .e ,I 1 (L 60.34, 52M' IT) VERTICALLY AS { - = 4 k S4.tin..,+tMA.�...a./'.s�/•J NECESSARY 1 .ri•�_n_--- p �- p -- 6 - 0 - �. ®•-- 9 = � B�®gib' EY w�.w-�_W w-..mow w•�_w� _IY --w--_ w-- wF-_w —W—W- --w w.r�__ -_ - -MF �/ W R A I .. ^'�,,j•�,2''D.I.P. NOL Is21LP) - ^'�j ..y}•,/,,�- �/�!' p& /ppp 2 9ii! �' {� ! i :LL! I t✓.../ti/a..'�/aA✓./.As✓'- ABANDON MA FILL EXIST ro5 �A51NN00NED bTn B'S$ PIPE (AISILF)PER la BE ^ , , �_ 1 '! '��'•--- - `OPEC r.4te,J15) ��• 4 + -•-L 36.30.13,48.74LT TO L 25-56.34,6228'Rf- L5 1•1 - I' .. _._ - _ \..* I I r I ^.. - it �� 1 , ,2'oLP. PJ WL WZA'B ETD WR STI CASNG (:1tN�F). CASING EL:3n.ALOONTRACTOR SHALL DETERMINE IF ADo ZONAL- �I " -, --�_,• �y T COVER IS REQUIRED TO PROTECT CASING 8 WL CURING �•- ® € ]4 W $ 1 M1 $ I -41, I CONSTRUCTION. SEE DETAIL 82 ON WSD-I, i S yn 23 ) !1 L.LINE 24 ! 1 1 I * �a. n 1 I -4FOLEWIS ST- 1 1 li� I -._� WAA METER g���� W I ' -4 PR ILE ..'...wv.,-� .1' _ V'y I II k ! e UI P.YN, (s156L i { 26 '��IR - - "42"MW COVER ta .t --ilI {.._ •I. L!R 9. L71.7 V 01 MJxMJ VERT I { Ic < , 'i, • BENDJUJHRUST BLOCK 1 _ INV EL: 311,11 O 22171A7 1032B RT -- I- S' OJ.P. WL (15LF) L 24.39.59.79A TRT ; 1 I I .__ -_ _, -- - - _ 3p•�� "� .. h 8'DIM I .( JxMJ VEFIT Z DI RU I CUT -IN TEE I, Y15 EHO W THRV5T BLOCK '`. I 1 1 `. I ; ••_•_ _- �'�i MFTCHAR (3 EA) LOCK �N1( EL' 377 35 i x 1 • `• I PLUG P.X-iSEWER PIPE, L.,•' v -m1, 1 _ W�cQ 0 ECT TO EXIST, W r L 22.76,07,1 W.20 FIT TO L Z! 38.0�, iO3?D 1 L 24.3959, 10),IO' RT I 3 •i H TER SERVICE DIG V DIP, RJ NIL W 1WO STO WT STL CASING _ 1 % I 8' gMJxA1J W' BENq - n y E• J ) I 1 I 1- jrq MJ1MJ 45�BEND q OF PIPE E OCRTgN. U) z y ND VERIFY LOCATION, (S16gF W MIN. SSFT COVER. CASING W TNRV,ST BLOCK 1 .' £PTH SIZE AND W. EL: 371.10. I ) ABANDON AND FILL E7JST. % 44I I v '`� y Q = BEE DETAIL B2 ON W50.1, I \\\ I I "THRUST BLOCK ! V R y 7EWAL OF EAST. PIPE ' ! ,'1 \ j ( 6-WL PIPE (2131XF) \ll SAD FOR t6'L. 1 J B' WATER METER VAULT 1 ABANDON t .�12' D.I.P YAL (sBLF) PER SPEC 7-0&3 TO BE REMOVED. EXIST, VALVE i I (5) dial 4J Q 9yy I PLUG EAST. WATER PIPE r 3 L 2T.S0,.96TRT W I 12` q MJxMJ 400 L� �' •`"� sV 8'gMJ CAP "THRUST Bl,.::K I - 'i PLUG XIST. WATER '! ie BE D- W AAhN _ -.MI'= "THRUST RIOCK - - yF(�,PIPE (2 EA) - wee O O N r 1 f s.. '�)°''�-_.�-__DI',� L•�..T�-°�-'•"4•_r d-ao.�--cw-- "--av--w�,".==-,rW'-=='c3' -• yN r O BE ABAM-.�j�W= w 'fit •9 = � :aa'=� - � .d"�'i vY 'e 5 ) J - •.'t. 14+ 12• EXIST, 12 VOLN!L T BE ABANOU-NED EAST. 12•"t TO BE ABANOCNED y 4 m �1 I O K tar _ V tj� ,,�yT,� D.I.P.P. WI�l y1 1 C ,_____----,-,^ •� 8'"l x 1C NG S DIP. WL (saLF)../ (a9LF1 I SEE DETAIL C L 2G EX T. WART F S j I � ' {.� -----r-••' i " PLUG EXIST. WATER PIPE (Z EA- M- 5 c I, ; I 1p':. 1: , • • " - - 16' D.LP^ ILL (itOLHj t P - SHEET WS•7 I g W O WH74 i x II--`�i'"''i—' .-,._.-... .. .. _.....__ - .:_:_:_:_:-.-.-._.-.-•-.-.� 3S ,I { .s y .. ._.. ,._. _ AY- '� I - - sr -Aa• sr - ar -AR- ar - - -A9- sr - sr -AD S-gK-er=� sr - /iT -AB- T' ••_ "L •. •••w tz DJ P W1 (s43LF)-•_ _ � E4-L)NzF .. IN cw � pp' — w — w wt2— W — W -24- w • ,. ;(EXISTMG))LEWIS STIREET W , j IJ rl SEE UP-28 AND UP-3 V ~ I - - _ - f - - - 17 D I.P. WA. W51 ��d' ..-aFOR LF) os� wtn E - t A` ` �.:...x....wn4 . EL b•4.Op. 10.001T , EL 26.25.91, 4.W LT .• 16"FL 12-FL IN ECCENTRIC RED, SEE UP-312' DI y "' �. i• JND "THRUST KOCK 3 SEE N3-3 3 '. ( 1Y FCA EXIST. 6, N1l {t --------------------------------a % --------------=---=------------------- --------- ------- �" o-ac-_�rsa Nc=� ��tiar��r���f'!c���s= SEE UNDERPASS PREPARATION PUNS —1` (UP-1-UP-7)FOR WATER MA94 PROFILE AND CONSTRUCTION DETAILS THROUGH FXISRNG XIST. FIRE HYDRANT UNDER PASS I TO REMAIN SH,EETNUMBER: WS-4 NOTE:REFER TO SHEET WB-0 FOR ( EXIST. VALVE PHASING -_-_-• ---'L--_-_---••-__-----_ �----------------- I PER I I I D 2.3. TON rarloN ---'--- --._.--�_.�_ _ EL 17+60.74, 24.BB LT TEMPORARY CONNECTION ALLEY ABANDON EXIST. VALVE (� � ANSTALLTION MUMS: 12*FwQ'w Di I _ CUT -IN TEE W/ THRUST BLOCK 12- FCA (2 EA), CONNECT TO EXIST. 12'WA. PER COP STD DWG 1.1. DIG AND VERIFY LOCATION, DEPTH, B / { SIZE, AND MATERIAL OF EXIST. PIPE. i y4 3 -Sr-LSt--qT--Sr--9T--Si -s .ABANDONMENT MIST. WATER PIP (2 TEE AND FCAF, PLUG EXIST. WATER PIPE (2 EA), CONNECT WATER MAN TO SOUTH. I � { I ? { 8 J/ 3 17 D.I.P. W1L (xBLF) SEE WS3 { EL 17+68.79,4.WLT 1r MJri7FL OI TEE SEE W63 I WITHRUST BLOCK 10-FLxAU BFV (N) 1V WI.- 174901 j `SEE WS-3 EL 17.60.76,4AD'LT 1 12' MJ%10• FL d TEE WTHRUST BLOCK 17 FL w a" (M0 ; b I ~�-17 OJ.P. VAL (z32LF) 1 ' I I I { 8 t - EL 17+6h79, 27.SORT ( CONNECT TO EXIST. 10- WL DIG AND VERIFY LOCATION, S EL 17+6816.19.97'RT fI + OEFTH,SIZE, AND MATERIAL ;. OF EXIST. POPE. I PLI1G E%MST. WATEN RPE SJI. __sr-=si'-MY=I'sr -ICB- TlC d84F�'.�' PLUG EL 17-6177.26.36RT EXIST. WATER PIPE 7::FEXNOSTVHYDRANT AALVE EL 17+68.91. 34.27 FIT - TO REMAIN ADJUST VALVE BOX : .11 I li I � g --- 1 ' I � DETAL A (SEE SHEET WS-3) o —`""5 o SCALE IN FEET COMB VACUUN 2 N. PER I L 26.25.10,69.3TLT 1 it DI FLrFL TEE ' WITHRUST BLOCK, j INV EL 37210 12"FL.NU BFV (S) R 5 I 12. FLxr FL 01 RED ((WWjj I1 I 1 7 FLXMJ OV WRJ Ir RFCA IS) 6'pVAS' BEND (22 EA) EA) W THR THRUST } BLOCK 3T VERT OFFSET ^ - I j .I L 28+1B.98, 87,6T 1T 4`0.' I I J ,AIR RELEASE/AIR- VALVE ASSEMBLY :DP STD OM 2b 1 I 3 I ' L PILT-� PLUG EXIST. WATER Pied IST.WA ER 4 DETAIL B (SEE SHEET WS-4) A� I 0 5 1D SCALE IN FEET @ EL 26.17.76, 42.7SL7 1 h EXIST, FIRE NT� 1 I TO RE WATER RER PIPE. 1 PllXi EXIST PIPE j!a EXIST. VALVE O 1r D.I.P. WW (*IOLF) t J EL 25+2D.92, 2237LT O lr DI W" 90- BEND W THRUST BLOCK A EL 26-23,42.22.IT LT� @PLUG EXIST. WATER PIPE A 01r D.I.P. WL C1SLF)- DETAIL C (SEE SHEET III NOTES: 1.REFER TO SHEET VJS.0 FOR PHASING LTEMPCRARY CONNECTION ALLEY E •INSTALLATION INCLUDES: ITEMS IDENTIFIED BYO •ABANDONMENT INCLUDES. ITEMS IDENTIFIED BY@ L 26+31.90.70.69' LT it M W FL DI TEE W W AND THRUST BLOCK 5' FU MJ GV CONNECT TO EXIST.wvaB DK3 AND VERIFY LOCATKN.DEPTIL SIZE_ AND MATERIAL OF EXIST, PIPE, 0 5 10 SCALE IN FEET EL 26.20.93, 32.3r LT % it 01 &WAN 97 BEND W THRUST BLOCK O CONNECT TO EXIST.12'YM DIG AND VERIFY LOCATION,DEPTH,SIZE. AND MATERIAL OF EXIST. PIPE PLUG EXIST. WATER PIPE O7 DKi AMC VERIFY ELEV. OF EXIST. 1r WN. ® CROSSING EL 26+25.92 22,36'LT O 1r 01 MJ%MJ 90- BEND W THRUST ROCK @REMOVE 97 BEND AND CONNECT WATER MAIN TO SOUTH o s 1D SCALE IN FEET V VS-! f"J U•B Baddiow AssemblV Above Ground Enclosure: Enclosures shall be provided for freeze FxlsnNo GRADE ,- REMOVE VALVE sox DovEa Ci m ,protection. Acceptable encbsures indudeAquastdeld, Weds Sate-T-Cover, and Hot Box ' m m SEE SPECIFICATIONS FOR tfibeiglass, stainless steel, Ornamental rock, and ornamental stump _ -.. ° bi m' � & ^ E BOX V.:':: FREEZE w PROTECTION IS REQUIRED 44.. _. '4''!`'-''^.:- �„AJ4.JwJa'•i"•1'.,A.'..: .A�.'!.'�'s+".m�°".. 3� 2'• W tQNL P°8 FP SEE NOTE 1 ~ ICLObyr'T%F ,� Z PP P 4 f SEE SPECIFICATIONS f L7 �'33 h raPVE ii SAFE -COVER Z UN ......�___.''.. Y ALU$M"MIBL:,.- ? I W o if nub' ' 60LTVALVE,.L, HEATED ENCLOSURE BD �. 10000-ALORAPPROVE 7' Do � EtlIAP. ANOi1at PER jSSS L CEN I-Q (K)Xa!7YIZ• s. •'fF-L MANUFACNNERSOXTHICK O(A:^.cTE PAD RECOMMENDATX**. 2REMOVEVALVSLOPiEFLOOR SEE NOTE6 _.E9) ANDFJ(TENBONTO rO.LP--'L9STH AB q �FILL VOID IF RO ND CEMENT E (ONLYTE�'�, ' TO ISLEVREQUIRED OF SURROUNDING GRADE (ONLY REQUIRED F VALVE 19 UNDER PROPOSED IYLO DRAa04E - ` 's �W eX.,t PAVED AREA SEE NOTE 2) y1+A'At • 1 tL r•Ir FLOOD PLAIN, 1�21•-9B'�. oCEw VVHW44EVER IB .�e MM 38•MIN+•I ," GREATER 1 CLOSE VALVE { (JStj EIUST. VALVE AND WATER MAIN ! 91.ffVE CRUSIr HED Y - �/ TO SE ABANDONEDMETER Box GFA6 CONT. Tl Ai7VL) wa5lc AND BOTTW f ASTMOISR ttff�� 9D• £1D VN 26•�MbIi OG - •• '�Li, — SPLICE TRACER IMRE CONTINUITY TOGETHER _ AND CHECK FOR CONTINUITY r f _ a.c•! `'. .. ..• - BASE OF ENCLOSURE 4,...,...�.:'.:': NOTES: ^..1 s'•'.Y:• f�i :• .:TOP OFtiAe +`;. •, E "i•v''%.%�y 24'MIN.,`•,� •�ELN.3TD75 "" t T. CLOSE VALVE PRIOR TO ABANDONMENT ;~T= may;; i•;•; :, ;; +•' •;riv-: + { (/Q, ABANDON EXIST, VALVE 2 B AREAS AND COMPACT, OF PROPOSED PAVEMENT, %£S 3rWN 24•ar ,J t ,F ..::' : • ' :+ ffff \ "1 SCALE: N.TS BACKFILL AND COMPACT iXa: FLOW BOX Ltj t LIIIIIIIIIIIII III IN I �y A PIPE .1. ... STEEL CASING PIPE IZM14 ! As- ,—WRAP AROUND END SEALS ARONDEIFSCORPEP BAAS _ _ - F •1 ! \f AT EI.CN CORNEA fOFt EACH j I DUCTILE IRON WATER MAIN aNrINuoLmelwra+AND RPDA & RPBA INSTALLATION raxr.-.crrnrs-ararj Z FORREDUCED PRESSURE DEFECTOR A9SFla31.Ya REDUCE PPE83lRE- ' CASING 99� O { .. v „_.r.v.. - �r -. �. [. Gw SPACER �. 7 r` Q m - i ,— ♦ FFF�y..f T •F PAD +, .t GAAOI91ON9, i ��.- \ In 4 S T .. .. NOMENENG7NEER Q C UU NOTES: - - J ( 1. MUUBEONTHELAiS I�Fi U�§T�A OiOSA(%A(i WPREVfMf10NA88EM�UES.•••J•-+•. �•.�•_..s_ ,?1'r:.. ./ 03 CT 3 2. MUST SE I STALLED ABOVE GROUND. MRO" IY CLEARANCE ABOVE THE FLOOD PLAIN AND IN THE ORIENTATION AS A `"-� N U q 12• W 0E AND TESTING G(REMOVABLEUSC ENCLOSLAB ANDURE E OR OPENS DENT. SIDE CE S TO THE T GT COCKS). FOR ROUTINE MAINTENANCE CDUCTA"t E UPON / STAINLESS STEEL BANDS y < d $ - AAID TESTRJG(REl10VA0lE ENCLOSURE OR OPENS ON THE SIDE PoRAGCE5870THE 71:St COCKS). TWIN. CLEAR - CARRIER PIPE TIGHTEN AS REQUP'ED N1 � S. OPITOVU.PVCSLEEVETOEXTENDrABOVEAN011--CONa>ET£PADTO-OWFOR SETnEMENTOFPAD. 0)O Q w y 4. FREEZE PROTECTION IS THE RESPONSa70.RY OF THE OW14M ---„ 1 J !•� ; 5. PIPE SUPPORTS ARE REQUIRED ON ASSEMBLIES OVER Y. CA61N O SPACER NOTES: S CASING PIPE e- 6. THE BACNROWASSEMBLY S TO BE TESTED AT THE TIME OF INSTALLATION BY A CERTIFIED TESTER APPROVED BY THE CITY UNLESS + ! 1. CASING SPACERS SHALL BE MANUFACTURED STAINLESS STEEL. Cj J POLYETHYLENE, OR EPa(Y COATED, SIZED FOR THE TYPE OF PIPE 2'MW. CLEAR. PRE -APPROVED CROSS CONNECTION SPECIALIST. `d a CASING SIZE PER 1TE MANUFACTURERS RECOMMENDATION. yt`-- {• T. THESEWASHI GTON O DEPARTMENT ASSEMBLY INSTALLATION STANDARDS REFLECT AFORMMREQUIR COOEa N COMPLY APPROVED DE 4.� SEE NOTE 3. 2. NOMINAL SPACING OF CASING SPACERS:13'OR u'LENGTH OF WASFiINGTON OEPARTAEMOF FRJLLTH REOIRATpNSM'AC 2d67Bo4a0F AND URFORM PLIIABRIG CODE, UNAPPROVED DEVUITON CARRIER PIPE•ARMMLIM OF 2 SPACERS PER STICKtg.2DLENGTH MAY RESULT INTHE CRY RE.ECTNG THE R75TAllA o AND THE CERTFICATEOF OCCUPANCY A6WELL ALL REQUESTS FOR ( vI a CARRIER PIPEMINIMUM OF 3 SPACERS PER SOCK INSTALL DEVIATION TO THESE STANDARDS MUST BE SUBMITTED R7 WRITING AND APPROVED BY THE CIT" CROS6•CDNNECTION SPECWJST. PER MANUFACTURERS RECOMMENDATIONS. 3. CASING SPACERS SMALL BE SIZED TO PROVIDE CLEARANCE FROM S fA __ CARRIER PIPE ID OF CASING PIPEACTUAL CLEARANCE AFTER INSTALLATION CITY OF PASCO -STANDARD DETAIL RPDA & RPBA INSTALLATION W-18 S \ MAY VARY DUE TO MINOR DEFLECTION OF CASING PIPE 5 .,� LARGER THAN 2' MIN. YLYEAR-- — PIPE BELL A. SEE SPECIAL PROVISIONS 7-09 FOR ADDITIONAL REOLNREMEMS. AT PIPE BELL SECTION A,A & END SEALS SHALL BE SPLIT WRAPAROUND STYLE WITH BUTYL a_-.•. �_.v._w_ti,�u �. w.....i w.+.�. MASTIC STRIPS FOR ADHESIVE, FLEXIBLE COAL TAR REINFORCED - '- .+.....wd✓`w_....�.rLa-"�"�'�. "-• " "I"^•-^-' ^-"`"'-'�.w•^� ^ ^-•'�^�"'-^=�•�+l'� WITH FIBERGlAS& MN. THCKNESS OF IV. WATERPROOF. g OP -STD DWG W-18,MODIFIED) BZ CASING SPACER AND END SEAL DETAIL SHEETNUMBER: 9CAlE; NTS W S D-1 (N) RPSA HEATED ENCLOSURE W(2) 2000W, 240V HEATERS S Y OTHERS) (E) U11UTY POWER POLE- COMBINATION UTILITY (N) UTILITY XFMR ER/SERVICE PANEL i I n- (N) 1- CND, 3 0 GND 4 /10, (N) GROUNDING ELECTRODE (I SYSTEM PER N.E.C.-----: " - B ELECTRICAL RISER DIAGRAM PANEL SCHEDULE FOR SERVICE PANEL. MEW DESCRIPTION S1 TOTAL VALET TOTAL VARK TOTAL VA TOTAL MPS 4 B A,P 00 1w 1000 0 2011 0 20/1 0 1000 1000 100D 1000 2000 20W1 17 17 (N) SERVICE RISER CONDUIT & WIRE (BY FRANKLIN PUD) SECONDARY JUNCTION (SEE NOTE 2) Load A B NOTES: 1. PROVIDE AND INSTALL (N) COMBINATION UTILITY METER/SERVICE PANEL. METER SHALL BE 120/24OV, 10, 3W, 4-JAW RING TYPE. PANEL MALL BE RATED 100 AMP NTH 40 AMP MAIN BREAKER AND INCLUDE BRANCH BREAKERS AS SHOWN ON SCHEDULE. UNIT SHALL BE EQUAL TO SQUARE D #SC162MIODS. PROVIDE SS UNISTRUT AND CONCRETE BASES AS REQUIRED TO INSTALL UNIT. 2. PROVIDE AND INSTALL (N) SECONDARY JUNCTION BOX PER FRANKLIN PUD DWG /272.VSIA, 3. PROVIDE AND INSTALL ALL CONDUIT AND WIRE FROM JUNCTION BOX TO METER/SERVICE PANEL AND TO RPDA HEATED ENCLOSURE. CONDUIT AND WIRE SHALL BE SCHEDULE 40 PVC AND TYPE 14HN/THWN. PROVIDE ALL TRENCHING AND BACKFILL AS REQUIRED FOR CONDUIT INSTALLATION. 4. PROVIDE WEATHERPROOF CONNECTIONS IN SECONDARY JUNCTION BOX AND RPBA HEATED ENCLOSURE AS REQUIRED. 5 CONTACT WAYNE REXN AT FRANKUN PUD FOR ANY SERVICE COORDINATION REQUIREMENTS (509-542-5347). 100 AAW PANEL WITH WIN BREAKER (40 MP) 1201240 VOLTS 1 PHASE 3 WIRE DESCRIPTION: _ COM O UTILITY AETERISERNCE PANEL SRKR VOLT•AlAPS AIP A S j DESCRIPTION 15f2 100D RPBAHEATER#2 1000 2011 0 �SPARE 20A 0 SPARE _--� 0 SPACE - ---- 0 SPADE TOTAL CONNECTED LOAD REMARKS: 4000 VA 17 MPS SERVICE PANEL W BNTEGRAL AFTER BASE TOTAL FEEDER DEMAND LOAD 4000 VA 17 MPS �Z CITY OFPASCO ELECTRICAL RISER DIAGRAM -• • LEWIS ST. OVERPASS & PANEL SCHEDULE Description C001 169 Field Office Trailer C002 DBE COA Deletion C003 A170 BNSF Crossing Permit 0004 A171 Girder Embedded Plates Sole Plates C005 A172 Added Drainage and Drywells Bridge Abt C006 A173 BNSF Force Account C007 C057 C07 Replace Waterline - Alley C & D C008 A174 Removal of Fuel Tank C009 A175 Unexpected Site Conditions -Subgrade C010 A176 Schedule 80 Conduit and Trenching C011 C058 Extra Waterline Work C012 C059 Clark St. Butterfly Valve C013 A177 BNSF Force Account 2 C014 A178 Remaining Subgrade FA C01S C060 Remaining Waterline FA C016 Sales Tax from CO 11 C017 A180 2022 Minor Changes Reconciliation C018 A181 BNSF Bridge 53 Rebar Modification C019 A182 SEW Subsurface Delay CO20 A183 Modification to Girder Sweep Means and Methods CO21 A184,185 Modified Approach Slab - Sleeper Slab and Strip Seal CO22 A186 BNSF Security Fence CO23 A187 BNSF Bridge No. Signs CO24 C061 Modified BNSF Water Service CO25 A188 Extended Overhead for SEW Redesign Delay CO26 A189 Increased Cost for Modifications to SEW Walls 3, 4, 7,8 Added Days Taxes 81 Total Current CO Total Previous Total To Date Total Contract 0 $ 3,065.56 $ 35,646.02 $ 38,711.58 $ - $ 38,711.58 $ 22,383,711.46 0 $ - $ - $ - $ 38,711.58 $ 38,711.58 $ 22,383,711.46 0 $ $ 100,000.00 $ 1001000.00 $ 38,711.58 $ 138,711.58 $ 22,483,711.46 0 $ $ 33,112.30 $ 33,112.30 $ 138,711.58 $ 171,823.88 $ 22,516,823.76 0 $ $ 16,915.44 $ 16,915.44 $ 171,823.88 $ 188,739.32 $ 22,533,739.20 0 $ $ 20,000.00 $ 20,000.00 $ 198,739.32 $ 208,739.32 $ 22,553,739.20 0 $ 12,290.12 $ 141,265.79 $ 153,555.91 $ 208,739.32 $ 362,295.23 $ 22,707,295.11 0 $ - $ 29,206.78 $ 29,206.78 $ 362,295.23 $ 391,502.01 $ 22,736,501.89 D $ $ 210,949.79 $ 210,949.79 $ 391,502.01 $ 602,451.80 $ 22,947,451.68 0 $ $ 36,559.01 $ 36,559.01 $ 602,451.80 $ 639,010.81 $ 22,994,010.69 0 $ 13,925.36 $ 13,925.36 $ 639,010.81 $ 652,936.17 $ 22,997,936.05 0 $ 302.92 $ 3,403.55 $ 3,706.47 $ 652,936.17 $ 656,642.64 $ 23,001,642.52 0 $ $ 10,000.00 $ 10,000.00 $ 656,642.64 $ 666,642.64 $ 23,011,642.52 0 $ $ 20,029.27 $ 20,029.27 $ 666,642.64 $ 696,671.91 $ 23,031,671.79 0 $ 398.47 $ 4,477.23 $ 4,875.70 $ 686,671.91 $ 691,547.61 $ 23,036,547.49, 0 $ 1,239.36 $ 1,239.36 $ 691,547.61 $ 692,786.97 $ 23,037,786.85 0 $ - $ 19,041.80 $ 19,041.80 $ 692,786.97 $ 711,828.77 $ 23,056,828.65 0 $ $ 41,160.96 $ 41,160.96 $ 711,828.77 $ 752,989.73 $ 23,097,989.61 0 $ $ 848,788.71 $ 848,788.71 $ 752,989.73 $ 1,601,778.44 $ 23,946,778.32 60 $ $ 77,192.65 $ 77,192.65 $ 1,601,778.44 $ 1,678,971.09 $ 24,023,970.97 0 $ $ 256,825.00 $ 256,825.00 $ 1,678,971.09 $ 1,935,796.09 $ 24,280,795.97 0 $ $ 20,000.00 $ 20,000.00 $ 1,935,796.09 $ 1,955,796.09 $ 24,300,795.97 0 $ $ 1,855.51 $ 1,855.51 $ 1,955,796.09 $ 1,957,651.60 $ 24,302,651.48 0 $ 11,631.41 $ 130,690.OD $ 142,321,41 $ 1,957,651.60 5 2,099,973.01 $ 24,444,972.89 Superior Accuracy. Zero Maintenance. NeptuneO MACH 100 Ultrasonic Meter 1P Pt ,t r The MACH 100 ultrasonic water meter features solid state ultrasonic technology including a factory - calibrated, replaceable unitized measuring element (UME) with no degradation of accuracy over time. Combined with a corrosion -resistant, lead free, high -copper alloy maincase, the MACH 10 is built to withstand demanding service conditions and deliver sustained accuracy over the life of the meter. • Sizes 3" through 12" • Extended low -flow range for superior leak detection • Accuracy sustained over meter life • Can be installed in both horizontal and vertical applications • Advanced ultrasonic technology with easily replaceable LIME design • Lead free, high -copper alloy maincase • UL Listed and FM Approved (standard) • Available in standard turbine and compound lay lengths • Open flow path design with low pressure loss • No maintenance • NePTUNe TECHNOLOGY GROUP #winyourday Specifications AWWA C715 Compliant NSF/ANSI 61 Certified UL Listed/FM Approved (Standard) Maximum Operating Water Pressure • 175 psi Operating Water Temperature Range +33°F to +122°F (+0.5°C to +50°C) Environmental Conditions Operating temperature: +14°F to +149°F (-10°C to +65°C) • Storage temperature: -40°F to +158°F (-40°C to +70°C) Applications • Potable water • Fire service • Reclaim water Warranty • Neptune provides a limited warranty for performance, materials, and workmanship. See warranty statement for details. System Compatibility • Compatible with Neptune R900® System. Also available as MACH 10®)R9001' for an integrated radio solution and MACH 10®)TC for Sensus Touch Coupler compatibility. Operating Characteristics Safe Maximum Extended Low Normal Operating Operating Capacity Meter Size Flow @ 100% Accuracy Range @ 100°k Normal (+/- 3.0%) Accurac (+1-1.5%) y Operation Fire Service (Non Fire Service) 3" 0.50 U.S. gpm 0.75 to 500 U.S, gpm 500 U.S. gpm 420 U.S. gpm 4" 0.75 U.S. gpm 1.5 to 1250 U.S. gpm 1250 U.S. gpm 1100 U.S. gpm 6" 1.0 U.S. gpm 2.0 to 2000 U.S. gpm 2000 U.S. gpm 1800 U.S. gpm 8" 4.0 U.S. gpm 6.0 to 4000 U.S. gpm 4000 U.S. gpm 4000 U.S. gpm 10" 6.0 U.S. gpm 10.0 to 6500 U.S. gpm 6500 U.S. gpm 6500 U.S. gpm 12" 8.0 U.S. gpm 12.0 to 8000 U.S, gpm 1 8000 U.S. gpm 8000 U.S. gpm Registration High Resolution (8-digit reading) 3" 4" 6" -12" 1 U.S. Gallons J J 10 U.S. Gallons J 0.1 Cubic Feet J J 1 Cubic Feet J 0.01 Cubic Metres J J 0.1 Cubic Metres J LCD Display 9-digit display for extra resolution on manual reads. Forward Flow + Warning for Excessive Flow Leak Reverse Empty Low I Flow Pipe Battery , AN. --,, r--:1 L0-0B.n0nRn0* P, C(QU---QU RATE 9Wr� On, gallons CU ft M3 t I L. __— __ __ -_ _. ___ l Rate and Units Cumulative Units Pressure Loss This chart shows typical meter performance. Individual results may vary. e V— 7.5 7 / 65 / it Ss / n 5 3. O 4.5 4' a 4 (` r— 6 g• ; w 3 / a zs J 1.5 100 ,No ,a000 Flow Rate (U.S. gpm) ® 2021 Neptune Technology Group Inc. All Rights Reserved. The trademarks, logos and service marks displayed in this document herein are the property of Neptune Technology Group Inc., its affiliates or other third parties. Availability and technical specifications are subject to change without notice. 21.005626 PS Cl MACH 10 3-12 05.21 Dimensions Meter Size L0-0B.n0nRn0* P, C(QU---QU RATE 9Wr� On, gallons CU ft M3 t I L. __— __ __ -_ _. ___ l Rate and Units Cumulative Units Pressure Loss This chart shows typical meter performance. Individual results may vary. e V— 7.5 7 / 65 / it Ss / n 5 3. O 4.5 4' a 4 (` r— 6 g• ; w 3 / a zs J 1.5 100 ,No ,a000 Flow Rate (U.S. gpm) ® 2021 Neptune Technology Group Inc. All Rights Reserved. The trademarks, logos and service marks displayed in this document herein are the property of Neptune Technology Group Inc., its affiliates or other third parties. Availability and technical specifications are subject to change without notice. 21.005626 PS Cl MACH 10 3-12 05.21 Dimensions Meter Size Length Height Weight 3" 12" 9'/2" 39lbs 17" 9'h" 42lbs 4" 14" 11" 51lbs 20" 11" 57lbs 6" 18" 12Y4" 79lbs 24" 123/4" — 91lbs a" 20" 15 bf" 1601b 5 264 Ibs 16" Width Available Units of Measure Consumption Rate Gallons GPM Cubic Feet GPM Cubic Metres LPM nitized Measuring lement (UME) Neptune Technology Group 1600 Alabama Highway 229 Tallassee, AL 36078 800-633-8754 334-283-7293 PENTA HEAD BOLTS (2) �<W o I� 1 a tp 3i +i t � Y � 1 FOR USE IN AREAS NOT SUBJECT TO VEHICULAR TRAFFIC 272.VS 1.1.DWG r— SECONDARY JUNCTION VAULT ANKLIN io DWN. DATE: 1/I0/07 DWG. NO. WR APP, D. SAMS UPDATM: ll,,22< 2019 272.VS1.1 THE POWER IS YOURS ENCLOSURE MODEL: IOOOD-AL JOB: ---- IRAWN BY: MTP SCALE: NONE DATE: 11/28/22 ELEVATION VIEW 18GA ALUMINUM - ROOF PANELS ARE REMOVABLE FOR MAINTENANCE 3" INSULATION ROOF (RI8) REMOVABLE ACCESS I TWO THIS SIDE TWO FAR SIDE I 384W x 78"H W 0 �n z 00 fl- I I I I i I HCH2O00-120 SLA8 MOUNTED HEATER ASSE 1060 TIF PLAN VIEW REMOVABLE ACCESS J TWO THIS SIDE TWO FAR SIDE 38i"W x 78"H I I I I 158" CONCRETE 1"" INSIDE BLE ACCESS 1 REMOVABLE ACCESS ` 384"W x 78"H 38z"W x 78"H t • r------- ------ HCH2O00-120 - HCH2O00-120 L— — — — — — L — — — — — — MOSURES OESOWD FOR THE VYORLDS Mf4TER SYSTEMS V&BSITE: SAFE-T-COVERCOM PHONE: (800, 2464M EMAIL: SALESjjBAFE-T•COVEH.COM FAIL.(81sl 2694 1 CONFIDENTIAL: THIS DRAWING IS INTENDED FOR USE ONLY BY THOSE AUTHORIZED TO RECEIVE IT. DISSEMINATION, DISTRIBUTION OR COPY OF THIS INFORMATION IS STRICTLY PROHIBITED. US PATENT 5,609,784 IL J o a - I o � o W o UJ o = U) W Z 00 N � O � X OJ W w � 00 r` J p X cn Q N _ O p Z = a d W Lu nf O in X W -i oO Ix V c' Z O Z d O 1: W O` U Lo 10 n N — rn C6 (n W LU Z W W J — Z Z U Sc z UU L F m O a Z Z }- (n O O 1- Z H H O O Q Q � N J U W N in Z X: Z Z 0 J J Q LL. Q NrM4 ENCLOSUWS DESIGNED FOR THE WORLDS WATER SYSTEMS'" • Roof, walls, and drain panel — 5052-H32 marine grade aluminum (.050118 gauge), mill finish, ASTM B209 outside • Drain panel hinge and spring — stainless steel • Insulation 1%" (9 "R" value) minimum thickness polyisocyanurate foam laminated to a glass fiber reinforced facer (each side), non -wicking • Mounting hardware — 300 series stainless steel or T 6 aluminum • Wedge anchors — Powers SDI -'/2" x 33/4" rrrr+.rw+ • ASSE 1060 • ASTM B209 El Yes — see separate specification submittal sheet ❑ No Specification Submittal Sheet Series 1000 — Panel Design Insulated Enclosures The enclosure is designed to provide freeze and vandal protection of above ground backflow prevention assemblies, meters, PRV, etc. The enclosure provides for safe and easy testing and maintenance. The enclosure disassembles easily if full equipment replacement is needed. l= — Model Inside Dimensions Concrete Pad Ship Access Access Panel Size Drain Opening W L H W L H Weight Panels W H W H 1000-AL T 40 144 80 54 158 6 580 3 38'% 80 38% 6Y2 1000D-AL 90 144 78 104 158 6 761 4 38Y4 78 38Y44 6'/2 1 1000DS-AL 90 174 78 104 188 6 896 4 38'/4 78 38'/4 6Y2 1000LU880-AL* 48 48 56 62 62 6 330 2 _ 40 56 40 6'/2 1000S-AL 1000T-AL 40 40 174 144 78 90 54 54 188 158 6 6 632 588 4 3 38% 38'/4 78 90 38% 38'/, 6'/ 6'/ 1000TD-AL _ 90 144 90 104 158 6 827 4 38% 90 38% 6Y2 1000TDS-AL 1000TLU880-AL* 90 64 _ 174 48 90 56 104 78 188 62 6 6 1035 397 4 2 38'% 56 90 56 38% 56 6'/2 6% 1000TS-AL 40 174 90 54 188 6 708 4 38'/4 90 38Y44 6Y2 1000TLU880M-AL* 63 57 62 77 T71 6 536 2 40 _ 62 40 �6'/ *Standard compact design models include hinged lift -up roof All dimensions in inches. A freeze and vandal protective enclosure shall be installed over above ground plumbing systems. The enclosure shall be constructed of 5052-H32 marine grade aluminum with a minimum R9 in the walls and R18 in the roof. Molded fiberglass enclosures will be rejected. Cut board insulation shall be used for uniform insulation thickness. Sprayed insulation shall be reason for rejection. Redwood post and beams shall be utilized for structural support. The use of "Particle board" shall be reason for rejection. The roof of the enclosure shall be removable for maintenance. Enclosures requiring tape to seal the roof seams are prohibited. The enclosures shall have a fully insulated drain panel designed to remain closed, except when discharging water. The drain panel shall be sized to accommodate the maximum discharge for backflow installations. The enclosure shall be mounted securely to a concrete pad and remain locked even if outside screws are removed. All mounting hardware shall be furnished. The enclosure shall withstand winds up to 110 mph with standard anchoring hardware. Anchoring hardware designed for 130 mph winds will be available upon special request (130 mph hardware may require a thicker concrete slab). When heat is required, a slab mounted UL or ETL listed heater shall be provided that has been independently certified to meet the UL-2021 "Rain Test" for damp or wet conditions. Wall -mounted air heaters and self-regulating cables shall not be used as the heat source. The enclosure shall be certified to the most recent ASSE Standard 1060 (Class I or Class II). The insulated enclosure shall be a Safe-T-Cover Series 1000. Hydrocowl, Inc. Nashville, TN • Phone 1-800-245-6333 FAX (615) 259-4481 • www.safe-t-cover.com SS71020 1'A ! ENCLOSURES DESIGNED FOR THE WORLDS WATER SYSTEMS' • Heating element — steel sheathed; casted in type 380 aluminum; rated 2000W @120/240Vac • High temperature wire — type MGT or equivalent; 10 AWG; rated 600V, 450°C • Ring terminal — rated 600V, 900°F • Junction well — group B, C, D, E, F; Class I, Division II; rubber sea] provided with cover • Conduit, conduit fittings, thermostat — liquid -tight • Conforms to UL-2021 section 49 Rain Test • Certified to CAN/CSA C22.6 NO.46 • ETL Listed 108666 • Economical • Durable • Effective • Efficient ZL Specification Submittal Sheet Series HCH/HCHS Insulated Enclosure Slab Mount Heating System U.S. Patent 5,609,784 The Safe-T Cover slab mount heating system provides freeze protection to the plumbing & water works equipment installed within an enclosure. This patented heating system virtually eliminates heat stratification within the enclosure, which reduces energy consumption. By mounting the heater on the slab, freeze protection is provided to the underground vertical riser pipes. The system is designed to withstand water spray conditions inside the enclosure. The heater has been independently certified to meet section 49 of UL-2021 for damp or wet conditions. Model No. Voltage Wattage BTUH Phase Amps Length (in) HCHS500-120 120 500 1707 Single 4.16 23 HCHS1000-120� --- 120 1000 3413 Single 8.33 23 HCHS1000-240 240 1000 3413 Single 4.16 23 Two for HCH2O00-120 120 2000 6824 Single 16.66 37 100OD-AL HCH2O00-240 240 2000 6824 Single 8.33 37 120 volt is standard for 1000D-AL. Contractor needs to specify . 240 volt at time of order as indicated on sheet WSD-1. A slab mount heating system shall be installed to provide freeze protection for plumbing & water works equipment installed within an enclosure. The heating system shall maintain a temperature of +40°F at an outside temperature of —30°F. The heating system shall be installed on the concrete pad and designed to operate without damage or impeding performance during water spray conditions. A thermostat capable of a temperature control range of +40°F to +100°F with fittings suitable for watertight installations shall be provided. The slab mount heating system shall be a Safe-T Cover Series HCH or HCHS. The heater has been independently certified to meet section 49 of UL-2021 for damp or wet conditions.. Nashville, TN - Phone 1-800-245-6333 Fax (615) 2594481 • Website www.safe-t-cover.com SSS-1116 Safe-T-CoverTM BACKFLOW PREVENTION ASSEMBLY ENCLOSURE SPECIFICATION PART 1 GENERAL 1.1 WORK INCLUDED A. Provide manufactured backflow prevention assembly enclosure. 1.2 QUALITY ASSURANCE A. Qualifications: The backflow prevention assembly enclosure manufacturer shall be a company specializing in the manufacture of backflow prevention assembly enclosures with at least 5 years of successful experience designing and selling enclosures to various customers in different climatic regions. 1.3 STORAGE AND HANDLING A. Store products in shipping containers and maintain in dry place until installation. 1.4 ACCEPTABLE MANUFACTURERS A. Safe-T-CoverTm or Engineer approved equal. 1.5 REFERENCES A. ASTM 13209. B. ASSE 1060-Performance Requirements for Outdoor Enclosures for Backflow Prevention Assemblies. PART 2 PRODUCTS 2.1 MODEL NO. & SIZE A. Model No. shall be 1000D-AL. B. Inside dimensions shall be 90"W x 144"L x 78"H. 2.2 MATERIALS OF FABRICATION A. Material of fabrication shall be 5052-1132 marine grade aluminum (.050/18 gauge), mill finish and shall meet ASTM B209. B. Insulation shall be 1.5" (9.0"R" value) minimum thickness polyisocyanurate foam laminated to a glass fiber reinforced facer (each side). The insulation shall have the following properties: 1. Dimensional Stability -Less than 2% linear change, ASTM D-2126; 2. Compressive Strength-20PSI, ASTM D-1621; 3. Water Absorption -Less than I% by volume, ASTM C-209; 4. Moisture Vapor Transmission -Less than one (1) perm, ASTM E-96; 5, Product Density -Nominal 2.0 lbs. per cubic foot, ASTM D-1622; 6, Flame Spread=25, ASTM E-84; 7. Service Temperature= -100QF to +250OF maximum. 8. The insulation shall be of uniform thickness. HCF1000D-AL-1 C. Structural members shall be redwood. 2.3 ROOF, WALLS & PANELS A. The roof, walls & panels of the enclosure shall be constructed of 5052-H32 (.050/18 gauge) marine grade aluminum, mill finish, ASTM B209 outside with insulation 1 1/2" (9.0 "R" value) thick in the walls and panels and 3" (18.0 "R" value) thick in the roof. B. The aluminum, insulation and redwood shall be securely bonded together to form a composite panel. C. The aluminum panels shall be provided with a PVC or similar exterior film to prevent damage before installation. The film shall be removed before installation. D. The complete assembly, including valve stems, shall be protected by being inside the enclosure. E. The roof shall be securely attached to the walls with screws and inside roof connections F. All screws shall attach to redwood members. G. The walls of the enclosure shall be securely attached to the concrete base with inside anchoring brackets. H. Access panels shall be four (4) in number and each shall be 38 1/4"W x 78"H. Two access panels shall contain drain panels. I. Access panels shall be completely removable. J. Access panels shall be provided with built-in pad lockable folding T-handles. K. Clear opening drain panel area shall be 38 1/2"W x 6 1/2"H. L. Drain panel shall have a stainless steel hinge and a stainless steel light strength spring as a positive means of closure so that the drain panel will not be activated by wind. M. Drain panel shall be designed to remain closed except during water discharge. 2.4 Heating Equipment (ASSE 1060 Class I -Required; ASSE 1060 Class H-Optional) A. Heating equipment shall be furnished and designed by the manufacturer of the enclosure to maintain an interior temperature of +40OF with an outside temperature of -300F. B. The heater shall have two electrical resistance elements completely enclosed within a solid aluminum cast platen base. C. The platen heater shall be designed for installation to the concrete base with mounting hardware provided. HCFI OOOD-AL-2 D. The platen heater shall be suitable for installation underneath a reduced pressure zone device and designed to sustain water spray without damage to or impeding the performance of the heater. E. The platen heater shall be provided with a thermostat adjustable from +40°F to +100°F. The thermostat, all conduits and wiring fittings provided shall be suitable for "water -tight" installation. 2.5 MOUNTING HARDWARE A. Mounting hardware shall be furnished and shall be 300 series stainless steel and/or T-6 aluminum. B. All threaded fasteners shall be furnished and shall be 400 series stainless steel and/or Hilti type Tap -Fast w/QuickcoatTM and Flo Seal washer or equal. C. All masonry fasteners shall be furnished and shall be stud type Hilti Kwik Bolt IlTM and/or Hilti type Hit Anchors or equal. D. All necessary drill bits shall be furnished. PART 3 INSTALLATION A. Enclosure shall be mounted on a concrete pad 104"W x 160"L x 6"Thick. B. Enclosure shall be assembled and mounted to concrete pad according to manufacturer's instructions. C. Enclosure shall be assembled and mounted to concrete pad in such a way that it will remain locked and secured to pad even if outside screws are removed. HCF1000D-AL-3 CITY OF PASCO Paso PUBLIC WORKS DEPARTMENT CONTRACT CHANGE ORDER NO.25 I ❑ Standard X Unilateral Project No: Project No: 13007 Project Title: Lewis Street Overpass FED -AID #: STPUS-HLP-3530(006) WSDOT: TA4087 Contractor: Cascade Bridge LLC Reason for Change: SEW Redesign Delay Detail as Appropriate: This change order adds one new item, A-188 Extended Overhead for SEW Redesign Delay. This item shall be full compensation for all direct and indirect overhead costs resulting from the project time extension caused by the redesign of SEW Walls 3, 4, 7, and 8. Per schedule analysis performed by the City's Construction Managment Represenative, WSP, the Contractor is due 119 additional working days related to SEW wall modifications. 67 of the 119 additional working days are compensable at the Contractor's established overhead rate. Contract Bid Amount: SALES TAX @ 8.6%: Total: $22, 344,999.88 $ 22,344,999.88 PREVIOUS CHANGE ORDER CURRENT CHANGE ORDER Subtotal $2,071,045.17 Subtotal $ 997,699.01 Sales tax (rate varies) $28,927.84 Sales tax @ 8.9% Total $2,099,973.01 Total $ 997,699.01 Total Change Orders To Date New Contract Amount IS CONTRACT TIME AFFECTED BY THIS CHANGE ORDER Contract Time Prior to this Change Order ................................ Modification to Contract time by this Change Order .................... Revised Total Contract Time ................................................. $ 3,097,672.02 $ 25,442,671.90 YES 460 119 579 It is mutually agreed by both parties that this Change Order fully describes the change(s) that is (are) being made and that the compensation for this Change Order is full and complete and is the only compensation due or owing for this Change Order. Further, it is mutually agreed that this document will supplement the present Contract Documents and that the provisions of the previously executed Contract Documents shall apply to this Change Order. AGREED TO AND ACCEPTED: CONTRACTOR Date APPROVED: APPROVED: PROJECT MANAGER Date APPROVED: CONST. MANAGER Date CIP MANAGER Date PUBLIC WORKS DIRECTOR Date Add the Following Bid Items: Bid Item: A-188 Extended Overhead for SEW 1 LS $ 997,699.01 Redesign Delay Sales Tax 8.9% Subtotal, Additions ........................•........•• Total this Change Order .......................................... • • • • • $ 997,699.01 CITY OF PASCO PUBLIC WORKS DEPARTMENT CONTRACT CHANGE ORDER NO. 26 Standard X Unilateral Project No: Project No: 13007 Project Title: Lewis Street FED -AID #: STPUS-HLP-3530(006) WSDOT: TA4087 Contractor: Cascade Bridge LLC Reason for Change: Modified SEW Walls 3, 4, 7, 8 Detail as Appropriate: This change order increases the quantity of existing item A-167 by 5,058 CY at the existing bid unit price. This change order will also delete Item A-038 and replace it with a new item, A-189 Revised Structural Earth Wall, for modifications required to SEW Walls 3, 4, 7, 8 . These items shall be full compensation for all the additional labor, materials, tools, and equipment necessary to provide and install the revised SEW Walls 3, 4, 7, and 8, due to the August 2022 redesign. Contract Bid Amount: SALES TAX @ 8.6%: Total: $22,344,999.88 $ 22,344,999.88 PREVIOUS CHANGE ORDER CURRENT CHANGE ORDER Subtotal $3,068,744.18 Subtotal $ 566,769.00 Sales tax (rate varies) $28,927.84 Sales tax @ 8.9% Total $3,097,672.02 Total $ 566,769.00 Total Change Orders To Date $ 3,664,441.02 New Contract Amount $ 26,009,440.90 IS CONTRACT TIME AFFECTED BY THIS CHANGE ORDER Contract Time Prior to this Change Order ................................. Modification to Contract time by this Change Order .................... Revised Total Contract Time ................................................. NO 579 0 579 It is mutually agreed by both parties that this Change Order fully describes the change(s) that is (are) being made and that the compensation for this Change Order is full and complete and is the only compensation due or owing for this Change Order. Further, it is mutually agreed that this document will supplement the present Contract Documents and that the provisions of the previously executed Contract Documents shall apply to this Change Order. AGREED TO AND ACCEPTED: CONTRACTOR Date APPROVED: APPROVED: PROJECT MANAGER Date APPROVED: CONST. MANAGER Date CIP MANAGER Date PUBLIC WORKS DIRECTOR Date Add the Following Bid Items: Bid Item: A-167 Gravel Borrow for SEW Ind Haul A-038 Structural Earth Wall A-189 Revised Structural Earth Wall Sales Tax 8.9% Subtotal, Additions ............ • • • • ............................... Total this Change Order .......................................... • • • • • 5,058.00 CY $ 151,740.00 (55, 065.00) SF (2, 202, 600.00) 53, 421.00 SF $ 2, 617, 629.00 $ 566,769.00 CITY OF PASCO I�dSCOI PUBLIC WORKS DEPARTMENT CONTRACT CHANGE ORDER NO.27 I X Standard ❑ Unilateral Project No: Project No: 13007 Project Title: Lewis Street Overpass FED -AID #: STPUS-HLP-3530(006) WSDOT: TA4087 Contractor: Cascade Bridqe LLC Reason for Change: Phase 1A Traffic Control Detail as Appropriate: This change order adds traffic control plans TC-7 and TC-7A for Phase 1A traffic control on the east and west end of the project. Quantities are increased for bid item A-111 Temporary Barrier by 350 LF. Bid Item A-136 Temporary Pavement Markings - Short Duration and A-133 Other Traffic Control Labor (labor for installing and maintaining the traffic control devices fro Phase 1A) will be tracked and paid under the existing bid items. One new item, Phase 1A Traffic Control, is added. This item is full compensation for all management, surveying, materials (cones, barrels, barricades, temporary signing, etc.), tools, and equipment necessary to implement the Phase 1A Traffic Control. Public outreach and traffic signal modifications shall be performed by the City of Pasco. Schedule impacts for this change order have not been quantified yet and will be addressed on a later change order if determined valid. Schedule impacts may include additional contract time and/or additional costs associated with this time. Contract Bid Amount: SALES TAX @ 8.6%: Total: $22,344,999.88 $ 22,344,999.88 PREVIOUS CHANGE ORDER CURRENT CHANGE ORDER Subtotal $3,635,513.18 Subtotal $ 45,600.00 Sales tax (rate varies) $28,927.84 Sales tax @ 8.9% $ - Total $3,664,441.02 Total $ 45,600.00 Total Change Orders To Date $ 3,710,041.02 New Contract Amount $ 26,055,040.90 IS CONTRACT TIME AFFECTED BY THIS CHANGE ORDER Contract Time Prior to this Change Order ................................ Modification to Contract time by this Change Order .................... Revised Total Contract Time ................................................. NO 579 0 579 It is mutually agreed by both parties that this Change Order fully describes the change(s) that is (are) being made and that the compensation for this Change Order is full and complete and is the only compensation due or owing for this Change Order. Further, it is mutually agreed that this document will supplement the present Contract Documents and that the provisions of the previously executed Contract Documents shall apply to this Change Order. AGREED TO AND ACCEPTED: CONTRACTOR Date APPROVED: CONST. MANAGER Date CIP MANAGER Date Add the Following Bid Items: Bid Item: A-111 Temporary Barrier A-186 Phase 1A Traffic Control Sales Tax 8.9% Subtotal, Additions ............................................... Total this Change Order .......................................... • • • • • APPROVED: PROJECT MANAGER Date APPROVED: PUBLIC WORKS DIRECTOR Date 350.00 LF $ 9,100.00 1.00 LS 36,500.00 $ 45,600.00